Definition
Vacuum is a space with a pressure lower than atmospheric. A perfect vacuum, with no matter, is a limit that is never reached: some gas always remains. That is why vacuum is described by how low the pressure is, not by total absence.
Two ways of expressing it
- Absolute pressure. The actual value of the pressure relative to physical zero. This is the recommended form, because it does not depend on the weather.
- Gauge vacuum. The difference below local atmospheric pressure, sometimes given as a negative value. It changes with atmospheric pressure, which makes it ambiguous at deep vacuum.
An absolute pressure is never negative. “Negative” readings always come from a gauge reference.
Vacuum levels
They are classified as low or rough, medium, high and ultra-high vacuum. The behavior of the gas changes in each range:
- Viscous regime. At higher pressures, molecules collide mainly with one another and the gas flows as a continuous fluid.
- Molecular regime. At very low pressures, molecules collide mainly with the walls. The conductance of the ducts and the way of pumping depend on the geometry.
Why it matters for measurement
No single sensor covers the whole range. Diaphragm gauges work in low and medium vacuum. Thermal gauges, such as the Pirani, cover an intermediate range, but their reading depends on the type of gas. Ionization gauges are used in high vacuum. Choosing the wrong gauge gives readings with no physical meaning.
Units
The pascal, the millibar and the torr are among the units used. When comparing figures, check the unit, especially in documentation for equipment of different origin.
What the engineer sees
A system that does not reach the expected vacuum may have a real leak, a virtual leak from outgassing of the walls, a degraded pump, or a poorly chosen or contaminated gauge. Telling them apart requires observing how the pressure changes when the pump is isolated.
Safety
Chambers and vessels under vacuum withstand stresses from the external pressure, and glass can implode. The work must be carried out by qualified personnel, with the applicable protection and procedures.