What is orthogonal frequency division multiplexing?

Orthogonal frequency division multiplexing (OFDM) distributes data across many narrow subcarriers that are orthogonal to each other, so that each one sees a nearly flat channel and the system withstands multipath better.

The starting problem

When transmitting at high speed on a single carrier, symbols are very short and multipath echoes overlap the following symbols. Correcting this requires a complex equalizer. OFDM turns the approach around: instead of one fast stream, it uses many slow streams in parallel, each on a different subcarrier. With longer symbols, echoes affect only a small fraction of the symbol.

What orthogonal means

The subcarriers are spaced at exactly the inverse of the useful symbol duration. With that spacing, even though their spectra overlap, each one passes through zero at the center of the others, and the receiver can separate them with no interference between them. This uses bandwidth very efficiently. In practice it is implemented with the fast Fourier transform, inverse in the transmitter and forward in the receiver.

The cyclic prefix

The final part of each symbol is copied to its beginning. If the maximum path delay is less than that guard interval, the echoes fall within the prefix and do not contaminate the useful part, and orthogonality is also maintained. It costs some efficiency in exchange for simplifying equalization to one adjustment per subcarrier.

Advantages and limitations

  • Robustness against frequency-selective channels: it is enough to adapt each subcarrier, and even to omit those sitting in a notch.
  • Flexibility: subcarriers can be assigned to different users, or the modulation can be adjusted per subcarrier.
  • High peak-to-average power ratio: the sum of many subcarriers produces peaks, and the amplifier must work with headroom or with reduction techniques, which penalizes efficiency.
  • Sensitivity to frequency errors and the Doppler effect: orthogonality is lost and intercarrier interference appears.

What the engineer sees

The spectrum of an OFDM signal looks like an almost rectangular block with steep edges. In the time domain, the envelope resembles noise. Quality is evaluated with the constellation of each subcarrier and with the error vector magnitude, and a synchronization failure appears as a rotated or smeared constellation.