Two different properties
Resolution is a property of the indicator: the smallest step it can distinguish or display. Accuracy is a property of the measurement: how close the result comes to the true value, expressed as an uncertainty or as error limits. One does not imply the other.
An example to illustrate it
Imagine a digital voltmeter that displays many digits and settles on a value, while another with fewer digits shows a slightly different reading. The first looks more precise, but if its internal reference has drifted or its gain is out of adjustment, every reading will be shifted from the real value. More digits only mean the error is displayed in more detail.
It is like a ruler with very fine divisions that was printed with an offset: you can read fractions of a millimeter, and all of them are wrong by the same shift.
How they relate to other terms
- Repeatability: how closely successive readings of the same thing agree under identical conditions. An instrument can repeat very well and still be biased.
- Uncertainty: expresses the interval within which the true value is expected to lie, and includes several contributions, among them resolution.
- Bias or systematic error: the constant difference from the true value, which calibration makes it possible to estimate and correct.
Where resolution comes in
Resolution sets a floor on uncertainty: a value can never be stated in finer detail than the indicator’s step. That is why it is included as a contribution in the uncertainty calculation. However, a resolution far beyond the specified accuracy offers digits that provide no useful information.
What to do in the field
- Read the accuracy specifications in the data sheet, which normally combine a percentage of reading and a term tied to the range.
- Choose the range that makes the best use of the scale without saturating.
- Verify or calibrate against a traceable standard when the decision depends on accuracy.
- Let the instrument stabilize and respect the environmental conditions in the specification.
Common mistakes
- Choosing an instrument by its number of digits.
- Treating precision, repeatability and accuracy as synonyms.
- Reporting a result with more figures than the uncertainty supports.
- Assuming a new instrument is accurate without evidence of calibration.