Definition
Instead of describing a vibration in hertz, its frequency can be expressed divided by the rotational frequency. The result is the order. A component at one times rotational speed is order 1, one that occurs at twice that speed is order 2, and there are also non-integer orders associated with rolling elements or gears.
What it is used for
Many vibration sources in a rotating machine are tied to rotational speed. If the speed changes, their frequencies in hertz shift, but their orders do not. An order spectrum aligns those components in the same position even when the speed varies, which makes it easier to track and compare them in startups, shutdowns and variable-speed machines.
Orders and typical faults
- Order 1: unbalance, and also bent rotors or eccentricity.
- Order 2 and above: misalignment, and generally looseness when several harmonics appear.
- Fractional orders: below one they appear in phenomena such as oil whirl, and between integers in components tied to bearings and gears.
- Number of teeth or vanes: the gear mesh or vane pass frequency is an integer multiple of the rotational speed.
How it is obtained
The speed must be known precisely, normally with a tachometer or a phase sensor that delivers one pulse per revolution. The instrument resamples the signal according to the rotation (order analysis) or converts the frequency axis to orders using the measured speed.
How to interpret the result
If a peak keeps its order when the speed changes, it is tied to rotation. If it keeps its frequency in hertz, it is linked to another source, such as the power grid or a fixed resonance.