What is regenerative braking?

Regenerative braking uses the electric motor as a generator during deceleration: it converts part of the vehicle's kinetic energy into electricity that recharges the battery, and it reduces the work of the friction brakes.

How it works

When the accelerator is released or the brakes are applied, the traction inverter reverses the direction of power flow: the motor, driven by the wheels, generates voltage and current that the inverter rectifies and sends to the battery. The generating torque slows the vehicle. It is the same equipment that propels it, working in reverse.

Why it does not recover all the energy

  • There are losses in the motor, the inverter and the battery at each conversion.
  • Energy is dissipated in air resistance and rolling resistance as the vehicle moves.
  • At low speed, the motor generates little torque and regeneration almost disappears.
  • The power the battery accepts is limited.

When it is limited

If the battery is full or very cold, it does not accept charge at as much power and the system reduces regeneration. In those cases the vehicle feels different when braking and relies more on the friction brakes. The vehicle control blends the two automatically so that the driver perceives continuous braking.

What an engineer observes in practice

Friction brakes wear less, but they can build up corrosion from lack of use, something that must be taken into account in maintenance. The vehicle data show negative battery current during deceleration, and the difference between energy delivered and recovered makes it possible to estimate the efficiency of the cycle.

How to interpret the gain

Recovery contributes more in city driving, with many accelerations and stops, and less on the highway at constant speed. It does not turn the vehicle into an energy source: it reduces net consumption, it does not cancel it.

Notice

The high-voltage systems of an electric vehicle or its battery can cause serious injury. Their inspection and repair must be carried out by qualified persons, following the manufacturer’s procedure and the applicable safety regulations.