Central idea
In conventional communication, the aim is to use the minimum bandwidth. Spread spectrum does the opposite: the signal is deliberately spread over a much greater width, controlled by a code that the receiver also knows. In exchange, the power density per hertz is low, the signal is hard to detect without the code and it is robust against disturbances concentrated at one frequency.
The two main techniques
- Direct sequence: each bit is multiplied by a sequence of faster pulses, called chips, which spreads the spectrum. The receiver multiplies by the same synchronized sequence and recovers the information; narrowband interference, by contrast, is dispersed in the process.
- Frequency hopping: the carrier changes frequency rapidly following a pseudorandom pattern. Fixed interference only affects the hops that land on its frequency, and the lost data are corrected with coding.
What is gained
Processing gain sums up the improvement: it is the ratio between the spread bandwidth and the information bandwidth. Thanks to it, the receiver can recover a signal whose level, before despreading, is close to or even below the noise in the spread band. In addition, different codes allow several users to coexist in the same band, and the signal withstands selective fading, because the information is distributed across the whole band.
What it costs
- Greater bandwidth per unit of information.
- The need for precise code synchronization in the receiver.
- With many simultaneous users, mutual interference grows and limits capacity, especially when received levels are very different.
What the engineer sees
On a spectrum analyzer, a direct sequence signal appears as a wide, low hump, sometimes barely above the noise floor. A frequency hopping signal looks like bursts at different frequencies; observing it requires a fast sweep mode or real-time analysis, otherwise it gets mistaken for isolated events.
A note on security
A signal being hard to detect does not mean it is encrypted. Confidentiality comes from encryption, not from spreading.