What it measures
Two vibrations of the same frequency can have equal amplitude and yet occur at different moments: one reaches its maximum when the other passes through zero. The difference in timing, expressed as a fraction of a cycle in degrees, is the phase. On its own, the phase of a single point means nothing: it is always measured relative to something.
How it is measured
- With a reference on the shaft: an optical sensor and a reflective mark, or a proximity sensor and a notch, deliver one pulse per revolution. The phase is the delay between that pulse and the maximum of the 1X vibration.
- With two channels: two accelerometers measure simultaneously at two points, giving the relative phase between them without the need for a reference on the shaft.
It is normally measured at a specific frequency, such as the rotating frequency, isolated from the rest of the signal.
What it is used for
- Unbalance: the phase is stable and, on the same support, the horizontal and vertical readings differ by about a quarter of a turn.
- Misalignment: usually shows a significant phase difference between the two sides of the coupling.
- Resonance: when crossing a natural frequency, the phase changes sharply.
- Looseness: unstable phase.
- Balancing: it is the information that makes it possible to locate the angle at which to add or remove mass.
How to interpret it correctly
- Always measure with the same sensor, at the same point and in the same direction.
- Verify that the reference pulse is clean and stable.
- Measure with the machine in steady-state operation, because the phase changes with speed near a resonance.
- Set an angle convention, either with or against the direction of rotation, and keep to it.
What it does not do
Phase does not provide the diagnosis on its own; it is interpreted together with the amplitude, the spectrum and the context. A phase that seems inconsistent may be due to a poor reference pulse rather than a machine problem.