What is shaft misalignment?

It is a lack of coincidence between the centerlines of two coupled shafts, whether through a parallel offset, an angle between them or both, and it generates additional forces in the coupling and the bearings.

Definition and types

When a motor drives a pump or a gearbox through a coupling, ideally both shafts rotate on the same line. If they do not, there is misalignment.

  • Parallel (or offset): the centerlines are parallel but separated.
  • Angular: the centerlines cross at an angle.
  • Combined: both defects at once, the most common situation.

Why it produces vibration

The coupling forces the shafts to follow a path that is not their natural one, and to do so it transmits forces and moments that repeat with each revolution. These loads act on the bearings and seals, which are subjected to additional stresses. The forces appear at the rotating frequency and its multiples, and are usually more pronounced in the direction joining the two shafts.

How it shows up

  • High vibration at 1X and often at 2X, with the 2X component being significant. The proportion changes with the type of coupling and the severity.
  • High axial vibration, characteristic of angular misalignment.
  • A phase difference close to half a turn between readings on either side of the coupling.
  • Elevated temperature at the coupling or in nearby bearings.
  • Recurring seal leaks, coupling wear or repeated bearing failures.

What causes it

  • Installation without proper alignment or with the wrong reference.
  • Soft foot, that is, a base that does not sit evenly.
  • Pipe strain on the casing.
  • Temperature changes: thermal growth moves the centers between the cold and hot conditions.
  • Foundation settlement or loosening of anchors.

How to tell it from unbalance

Unbalance mainly affects the radial direction and does not usually show high axial vibration. Misalignment, by contrast, tends to increase the axial vibration and shows that phase difference across the coupling. But certainty comes from combining spectrum, phase and a direct alignment measurement.