A bandwidth that depends on a criterion
The impedance of an antenna changes with frequency, and it matches that of the line only in the vicinity of its resonance. Moving away from it, the reflection increases. Impedance bandwidth is the span of frequencies where that reflection is tolerable. It has no universal value: the limit is chosen according to the system, normally expressed as a minimum return loss or a maximum VSWR. Two manufacturers can give different bandwidths for the same antenna if they use different criteria.
How it is measured
A network analyzer calibrated at the antenna connector is used. The reflection parameter is measured over a wide band and the frequencies at which the trace crosses the chosen limit are identified. The difference between those frequencies is the bandwidth. It is often expressed in fractional form, divided by the center frequency, which makes it possible to compare antennas from different bands.
Reading it on the Smith chart
On the Smith chart, the antenna impedance traces a curve as the frequency is swept. Near resonance, the curve forms a loop around the center, where the match is perfect. The bandwidth is determined by the portion of the loop that falls inside the allowed reflection circle. A small loop close to the center indicates a well-matched wideband antenna; a large loop that moves away quickly indicates a narrow band.
What it depends on
- Quality factor. An antenna with high reactive energy storage relative to what it radiates has a high quality factor and a narrow band. Electrically small antennas are limited by a fundamental relationship between size and bandwidth.
- Geometry. Thicker elements, gradually changing shapes and structures with several closely spaced resonances widen the band.
- Matching network. A network can improve the match over a band, but it does not exceed the physical limits of the antenna.
What it is not
It should not be confused with pattern or gain bandwidth, which is the range where the pattern, polarization and gain remain acceptable. An antenna can be well matched in a band where its pattern is distorted, and vice versa. When selecting an antenna for a system, both conditions must be verified, as well as that the installation environment does not detune it.