What is nominal operating cell temperature?

Nominal operating cell temperature (NOCT) is the temperature reached by a cell in a module mounted on an open rack, at open circuit, under 800 W/m² of irradiance, an ambient temperature of 20 °C and a wind speed of 1 m/s.

Definition and conditions

NOCT is determined with the module on a support open at the back, not connected to a load, with an irradiance of 800 W/m², an ambient temperature of 20 °C and a wind speed of 1 m/s. Under those conditions the cell temperature is measured. It is a reference value that describes how well the module dissipates heat.

What it is used for

Power falls as the cell heats up, so knowing its temperature is essential for estimating performance. NOCT makes it possible to calculate the approximate cell temperature at another irradiance and ambient temperature, assuming that heating above ambient is proportional to irradiance. It is a simple estimate that is useful in preliminary design.

Why reality differs

  • A module in operation delivers power, so it heats up less than at open circuit.
  • Actual wind varies and greatly changes the cooling.
  • Roof mounting, with little ventilation behind the module, raises the temperature compared with an open rack.
  • Modules with more efficient cells or with double glass behave differently.

How it is used with the temperature coefficient

The temperature coefficient of power, which the datasheet gives as a percentage per degree, indicates how much power falls as temperature rises. Together with the estimated temperature, it makes it possible to anticipate the thermal loss. In the field, direct measurement with sensors on the back of the module is more reliable than the estimate.

How to interpret the value

A lower NOCT indicates that the module stays cooler under the same conditions, which favors its performance in hot climates. It is not in itself a measure of quality: it is evaluated together with the temperature coefficient and the type of mounting.