What is instrumentation amplifier noise?

Instrumentation amplifier noise is the random signal the circuit itself adds to the measurement; it is specified referred to the input and determines the smallest signal that can be distinguished.

What it is and where it comes from

Every amplifier adds noise to the signal it processes. This noise originates in the input transistors and internal resistors, and it has thermal, discrete-charge (shot noise) and low-frequency components. In an instrumentation amplifier, designed for small sensor signals, this noise sets the practical resolution limit of the measurement.

How it is specified

  • Voltage noise spectral density, in nanovolts per root hertz: indicates how much noise there is per unit of bandwidth.
  • Current noise density, in picoamps per root hertz: the noise current from the inputs flows through the source impedance and becomes a voltage.
  • Low-frequency or 1/f noise, which grows as frequency falls and is usually specified as a peak-to-peak value over a low-frequency interval. The frequency at which it equals the white noise is called the corner frequency.

Referring noise to the input (RTI) expresses it as if it all came from a source at the input, which allows direct comparison with the signal. Referred to the output, the same noise appears multiplied by the gain, plus the noise of the output stage.

How it combines

Total noise is the root-sum-square of the independent sources, not their direct sum, and it grows with the square root of the measurement bandwidth. Reducing the bandwidth with a filter or by averaging lowers the noise reaching the result, at the cost of response speed. In addition, the source resistance contributes its own thermal noise, which increases with its value. A high-impedance source can dominate over the amplifier’s voltage noise and make the noise current weigh more.

What the engineer sees

With the input shorted and an oscilloscope or sensitive voltmeter, the output shows a noise band; dividing it by the gain gives the input noise. If the measured noise is higher than the specification, the cause is usually unshielded wiring, ground loops, power-line interference or a wider bandwidth than expected.

How to interpret the result

A signal can only be distinguished if it exceeds the noise integrated over the bandwidth of interest. To choose an amplifier, compare the noise density with the source impedance: with low-impedance sources voltage noise matters, and with high-impedance sources, current noise.