Definition
MTTR is the average of the repair durations for a set of failures. It is calculated by adding up the total downtime due to failures and dividing it by the number of failures. The abbreviation is also used with other meanings, such as mean time to recovery or to respond, so it is always necessary to state which interval is being measured.
What interval it includes
The practical definition changes according to the interest of whoever is measuring it. A useful breakdown separates these phases:
- Detection: from when the failure occurs until someone notices it.
- Notification and response: alert, assignment and travel of personnel.
- Diagnosis: identifying what failed.
- Waiting for spare parts or tools.
- Repair or replacement.
- Testing and return to service.
In many cases the repair itself is the shortest part. Diagnosis and waiting for spare parts usually dominate the total, so reducing MTTR is more a matter of organization and parts availability than of manual skill.
Relationship to availability
For repairable items, availability is approximated by the ratio of mean time between failures to the sum of that time and mean time to repair. It follows that availability can be improved in two ways: by spacing out failures or by shortening repairs. Equipment that fails frequently but is repaired quickly can have an availability similar to equipment that fails rarely and takes a long time to recover.
Limitations when interpreting it
- It is an average: a few very long repairs distort it. It is advisable to look at the median and the spread as well.
- Mixing very different types of failure produces a number that describes none of them.
- If the clock starts at detection and not when the failure occurs, the value underestimates the real unavailability.
What an engineer sees in practice
A work order log with notification time, arrival time, diagnosis time and closing time makes it possible to see where time is being lost. A design that facilitates access, interchangeable modules, built-in diagnostics and an inventory of critical spare parts reduce MTTR without touching the reliability of the equipment.