How is thermography used in electronics and circuit boards?

It is used to see how heat is distributed on a running board, locate components dissipating too much or short circuits, and validate the thermal design, using close-focus optics because the targets are very small.

What it is used for on a board

Every component that consumes power converts it into heat. A board in operation has a characteristic thermal map. Thermography makes it possible to compare it with a good board, with the expected design, or with an earlier version, and to detect deviations without touching the circuit.

What is detected

  • Components dissipating more than expected, for example because of an internal fault or poor selection.
  • Short circuits and leakage, which show up as a heating point along the path.
  • Traces or vias with abnormal resistance.
  • Heat sinks poorly mounted or without good thermal contact with the component.
  • Uneven current sharing between parallel components.

Specific difficulties

The first is size: a small component can occupy a single pixel or less, and its temperature is then underestimated. This is solved with close-focus or macro optics. The second is emissivity: plastic packages emit well, but pins, contacts, and shiny solder joints emit little and reflect. To measure absolute temperatures, a coating of known emissivity is applied or identical components are compared.

An example of use

A switching power supply that fails intermittently is run under load. The image shows that one transistor gets much hotter than its twin in another phase. This directs the check to that component, its drive circuit, or its contact with the heat sink, instead of replacing parts at random.

Good practice

  • Let the board reach a steady state before measuring, or capture the evolution over time if startup is of interest.
  • Keep airflow conditions controlled, because convection changes the surface temperature.
  • Take care with electrostatic discharge protection during handling.
  • Keep the same setup when comparing boards.