Technical guides
Clear explanations of concepts, methods, standards and measurements for engineers and technicians.
- Antennas 52
- Confined spaces 52
- Dielectric materials 54
- Dielectric oils 61
- Electric vehicles 52
- Electrical safety and PPE 52
- Electronic instrumentation 52
- EMC/EMI 53
- Environmental testing 53
- Grounding 54
- Industrial electrical systems 52
- Insulation and high voltage 61
- Metrology and calibration 59
- Oscilloscopes 53
- Power quality and Grid Code 61
- RF and microwave 61
- Solar energy 52
- Temperature and pressure 52
- Thermography 53
- Transformers 55
- Troubleshooting 52
- Vibration 52
- Wireless communications 52
- Linear or Circular Polarization?
Linear polarization keeps the electric field oscillating in a fixed direction; circular polarization makes it rotate. Linear is chosen when both ends hold a stable orientation, and circular when the orientation varies or rotation must be tolerated.
- Linear or switching power supply for testing
For noise-sensitive tests, such as analog or low-level circuits, a linear supply is the better choice; to deliver more power in less space with better efficiency, a switching supply, provided its noise is tolerable.
- Liquid bath or dry block for calibrating probes
A liquid bath offers better thermal uniformity and accepts probes of various shapes; a dry block is more portable and faster, but its accuracy depends on the fit between the probe and the well.
- Lithium-ion or lithium iron phosphate battery?
Lithium iron phosphate offers greater thermal stability and long cycle life in exchange for lower energy density; metal oxide chemistries with nickel offer more energy per unit mass but require more thermal care.
- Live work or de-energized work?
De-energized work is the rule because it eliminates the hazard at its root; live work is accepted only as a justified exception, with a specific method, tools and qualified personnel, because the risk depends on nothing going wrong.
- Logic analyzer or mixed-signal oscilloscope?
Choose a mixed-signal oscilloscope when you need to see the analog waveform alongside a few digital lines; choose a logic analyzer when you need many lines, very deep memory or state analysis synchronized to a clock.
- Long-wave or mid-wave camera?
Long-wave cameras are usually the general-purpose option for electrical and mechanical inspection because of their lower sensitivity to solar reflections and their cost, while mid-wave cameras are reserved for higher-temperature applications, high sensitivity, or gas imaging.
- Low-Noise Amplifier or Power Amplifier?
A low-noise amplifier is placed at the start of a receiver to add minimal noise to weak signals; a power amplifier is placed at the end of a transmitter to deliver the required output level with the necessary linearity and efficiency.
- Manual sampling or online monitoring?
Manual sampling with laboratory analysis offers a broad, precise profile at intervals, while online monitoring provides continuous tracking of a few parameters; in practice they complement each other rather than exclude each other.
- Manufacturer’s Tolerance or In-House Acceptance Criteria?
The manufacturer's tolerance describes what the instrument can do under specified conditions; an in-house acceptance criterion is defined by what your process needs to measure. You should apply the more demanding one that corresponds to your use.
- Measuring insulation at low or high voltage: what changes
Measuring insulation at low voltage reveals contamination, moisture and severe deterioration with little risk, while measuring it at high voltage subjects the insulation to stress close to service conditions and can reveal local weaknesses, voids and non-linear behavior that the gentler test does not detect.
- Mechanical or Electronic Calibration on a VNA?
Mechanical calibration uses physical standards that are connected one at a time; electronic calibration uses a module with switchable internal states. Electronic calibration is faster and more repeatable, while mechanical calibration allows the best reference when done carefully.
- Microwave Link or Fiber Optics?
Fiber optics offers greater capacity, lower and stable latency and immunity to electromagnetic interference, but requires conduit; a microwave link deploys faster and clears obstacles without civil works, but depends on line of sight and weather.
- Mineral oil or ester fluid for transformers?
Mineral oil has decades of experience behind it and costs less; ester fluids offer a higher flash point, biodegradability and better moisture tolerance, with differences in viscosity and in how tests are interpreted.
- Mineral oil or natural ester fluid?
Mineral oil and natural ester fluid are both valid liquid insulators with different profiles: ester offers a higher flash point and better moisture tolerance, while mineral oil offers more field experience, lower viscosity, and better oxidation stability.
- Modular data acquisition system or standalone instruments
A modular data acquisition system is the better choice when you need many synchronized, scalable channels under a single software package; standalone instruments, when you need maximum performance in a specific function or flexibility of use on the bench.
- Monocrystalline or polycrystalline silicon?
The difference lies in the structure of the silicon: monocrystalline silicon is formed from a single crystal and polycrystalline silicon from many grains. The former usually offers higher efficiency per unit area; the latter has historically been associated with lower manufacturing cost.
- Non-contact sensor or accelerometer?
The non-contact sensor measures the motion of the shaft relative to the support, and the accelerometer measures the absolute vibration of the casing; the former is chosen when the shaft moves freely within its bearings and the latter when the casing transmits vibration well.
- Off-load or on-load tap changer?
An off-load tap changer is operated only with the transformer de-energized and is used for occasional adjustments; an on-load tap changer changes taps in service and allows continuous voltage regulation, at the cost of greater complexity and maintenance.
- Oil reclamation or replacement?
Reclamation makes sense when the oil is degraded but the equipment and paper are still in acceptable condition, and replacement when contamination or deterioration is such that treating the oil is not enough or is not viable.
- Omnidirectional or directional antenna?
It depends on whether coverage must reach every direction in the horizontal plane or be concentrated toward one point: the omnidirectional antenna spreads the energy over 360 degrees with shorter range, and the directional antenna concentrates it with more gain in one direction.
- On-site or laboratory diagnosis?
On-site diagnosis sees the equipment in its real environment and avoids transporting it; laboratory diagnosis offers control, instruments and repeatable conditions. The failure and the conditions in which it appears decide which is better.
- Online or line-interactive UPS against grid variations?
An online UPS always feeds the load from the inverter and isolates it from the grid, with no transfer time; a line-interactive UPS passes regulated grid voltage and switches to battery only on a failure, with a brief transfer time.
- Online or Offline Partial Discharge Detection?
Online detection measures partial discharges with the equipment in service and without interrupting it, while offline detection uses a controlled test source, which allows calibration and the determination of inception voltages.
- Paper-Oil or Extruded Polymer Insulation?
Oil-impregnated paper is a system of cellulose layers with a fluid, with a long track record and sensitive to moisture; extruded polymer is a continuous material, lighter and simpler to install, but sensitive to trees and voids.
- Passive or active harmonic filter?
A passive filter is a tuned LC circuit, simple and economical, that traps specific harmonics; an active filter measures the load current, injects the opposite current using power electronics and covers a wide spectrum adaptively.
- Patch Antenna or Yagi Antenna?
A patch antenna is flat, compact and of moderate gain, ideal for integrating into surfaces or circuits; a Yagi is a structure of parallel elements with more directional gain, but it is bulkier and has a narrower band.
- Peak, quasi-peak or average detector?
The peak detector records the maximum value and is the fastest and most conservative; the average detector reflects the mean value of the envelope and is useful for continuous narrowband signals; the quasi-peak detector weights amplitude according to repetition rate. The following always holds: peak is greater than or equal to quasi-peak, and quasi-peak is greater than or equal to average.
- Permanent magnet or induction motor?
Permanent magnet motors offer higher efficiency and power density, but they depend on rare earth magnets and generate voltage when spinning; induction motors are robust and magnet-free, with lower efficiency at light load.
- Personal detector or area detector?
A personal detector protects the wearer by measuring the air they breathe; an area detector monitors the space in general from a fixed point. They complement each other: the area detector gives early warning, and the personal detector governs the decision to leave.