How is the signal on a line measured to detect an intermittent fault?

To detect an intermittent fault on a line, the signal is recorded continuously or with event triggering, so that the instrument captures the anomaly when it occurs even if nobody is watching.

The challenge of measuring what is not there

A multimeter shows the value at that instant, and it misses an anomaly lasting microseconds, or one second in hours of operation. Detecting an intermittent fault requires instruments that keep watch for you and save the evidence when something departs from normal.

Which instrument for each type of event

Event Suitable instrument
Very brief spikes or disturbances Oscilloscope with threshold, pulse-width or anomalous-event triggering.
Voltage dips or variations lasting seconds Event recorder or power quality analyzer.
Slow changes over time Data logger with periodic sampling.
Errors on a digital bus Logic analyzer with pattern triggering.

Procedure

  1. Decide which signal to observe: the suspect line, its power supply and a ground reference.
  2. Set the trigger to a condition that characterizes the fault, such as a voltage dropping below a certain threshold or a pulse that is too short.
  3. Configure the acquisition to save what happened before and after the trigger, so that the cause can be seen and not just the effect.
  4. Measure with a good probe ground connection, so as not to confuse measurement noise with real noise.
  5. Leave the equipment running and repeat until several events are captured.

How to interpret the result

Once an event is captured, look at its shape. A dip that appears when a load starts points to the power supply; a spike that coincides with a relay switching points to coupling; a sudden jump to zero with a mechanical knock points to a contact. Correlating the moment with other signals or with machine events shortens the search.

Precautions

The probe itself can alter the circuit, and capturing high voltages requires suitable probes and insulation. These measurements on energized circuits must be carried out by qualified personnel in accordance with applicable regulations.