Why it is needed
The high-voltage bus of a vehicle is floating: neither the positive nor the negative is tied to the chassis. In this arrangement a first insulation fault to chassis does not create a current loop and the system keeps running, but protection is lost. A second fault on the other pole does produce current. The monitor detects the first fault in time, before it becomes dangerous.
Measurement principle
Two families of methods can be distinguished:
- Voltage reference measurement: the voltage of each pole relative to the chassis is measured, with a switched reference resistor. Ohm’s law is used to calculate the leakage resistances of the positive and negative poles.
- Signal injection: a low-frequency signal or pulses are applied between the system and the chassis and the response is analyzed; this is useful when the system has large filter capacitors.
The result is a total resistance or the lower of the two poles, which is compared with warning and fault thresholds. The criteria come from the vehicle electrical safety regulations and the manufacturer’s specification.
What the engineer sees
- An intermittent warning that appears with humidity, rain or washing usually indicates a leakage path through water or condensation.
- An alarm that appears only with certain loads active, such as the high-voltage heater or the compressor, points to the subsystem being activated.
- When the alarm is permanent, the vehicle may restrict power or prevent the contactors from closing.
When it is not enough
The monitor measures the insulation; it does not locate the fault. To find it, subsystems are disconnected and measured with an insulation tester until it becomes clear which one restores the reading. The monitor does not replace an inspection either, and its reading depends on the settling time of the capacitors.
Work on these systems must be done by qualified people, with the vehicle deactivated and the absence of voltage verified, according to the applicable regulations.