What are the state of charge and state of health of a battery?

State of charge (SOC) indicates how much charge remains in a battery relative to its current capacity. State of health (SOH) indicates how much it has deteriorated compared with a new battery, normally through loss of capacity or increased internal resistance.

Two different quantities

SOC answers the question of how much is left now; SOH, how much the battery has aged. An old battery can be at one hundred percent charge and still store less energy than a new one. Confusing the two leads to misreading range and wear.

Why they are not measured directly

No sensor exists that measures stored charge. It is inferred from other variables, and each method has limitations.

How SOC is estimated

  • Coulomb counting: integrating the current flowing in and out. It is simple, but it accumulates error over time and depends on knowing the actual capacity.
  • Open-circuit voltage: the rest voltage is related to the charge, but this requires the battery to rest and, in some chemistries, the relationship is very flat.
  • Models and filters: these combine a cell model with voltage, current and temperature measurements and correct the counting error.

How SOH is estimated

It is usually based on the available capacity compared with the rated capacity and on the internal resistance compared with the initial value. Capacity falls with aging and resistance rises, which reduces the available power and increases heating. Rigorous measurement requires a capacity test under controlled conditions.

What an engineer sees in practice

The dashboard indicator can jump or behave strangely because SOC is an estimate. At low temperature, the available capacity drops temporarily and the indicator falls without the battery being damaged. An SOH reported by the BMS should be taken as a reference and checked against a capacity test when decisions are being made, such as a purchase or a warranty claim.

Notice

The high-voltage systems of an electric vehicle or its battery can cause serious injury. Their inspection and repair must be carried out by qualified persons, following the manufacturer’s procedure and the applicable safety regulations.