- What does ISO 6469-3 on electrical safety cover?
ISO 6469-3 specifies the electrical safety requirements for electric road vehicles: voltage classes, protection against electric shock, insulation, equipotential bonding and insulation monitoring of the high-voltage system.
- What does Section 38.3 of the UN Manual of Tests and Criteria test for batteries?
Section 38.3 of the UN Manual of Tests and Criteria requires lithium cells and batteries to pass a series of tests simulating transport conditions, such as altitude, temperature, vibration, shock, short circuit, impact, overcharge and forced discharge.
- What does the IEC 61851 conductive charging series cover?
The IEC 61851 series sets out the requirements for electric vehicle conductive charging systems: charging modes, the control pilot function, station electrical safety, and specific requirements for DC charging.
- What does the IEC 62196 connector series define?
The IEC 62196 series defines the requirements for plugs, socket outlets, connectors and vehicle inlets for conductive charging, including their dimensions, and the AC and DC connector types that make stations and vehicles compatible.
- What is a battery emulator?
A battery emulator is a programmable DC power supply that reproduces the electrical behavior of a battery, voltage according to state of charge and internal resistance, and can also absorb energy to test chargers and converters without a real battery.
- What is a battery module compared with a pack?
A battery module is a set of cells connected and held in a structure with sensing, and a pack is the complete system that groups several modules with a management system, contactors, protections, cooling and an enclosure.
- What is a DC-DC converter in an electric vehicle?
A DC-DC converter in an electric vehicle steps the high voltage of the traction battery down to the level of the low-voltage auxiliary network, performing the role of the alternator in a combustion vehicle.
- What is a dynamometer test bench for electric motors?
A dynamometer test bench couples the electric motor to a load machine that sets its speed or torque, and it measures torque, speed and electrical power to obtain curves and efficiency maps.
- What is a vehicle simulator for testing chargers?
A vehicle simulator for testing chargers is a device that imitates the vehicle toward the station: it generates the control pilot and proximity signals, emulates the battery's demand and makes it possible to induce faults.
- What is AC charging versus DC charging?
In alternating current charging, the vehicle receives AC and its onboard charger converts it to DC; in direct current charging, the charger is outside the vehicle and delivers DC directly to the battery. What changes is where the conversion takes place and, with it, the power possible.
- What is C-rate?
C-rate expresses charge or discharge current as a multiple of the battery's rated capacity: 1C is the current that, in theory, fully discharges it in one hour.
- What is cell self-discharge?
Self-discharge is the gradual loss of charge in a cell at rest, with no load connected. It is caused by parasitic internal reactions and small leakage currents, and it increases with temperature.
- What is depth of discharge?
Depth of discharge is the fraction of a battery's capacity that has been drawn from full charge; it is the complement of state of charge and largely determines wear per cycle.
- What is lithium-ion cell chemistry?
The chemistry of a lithium-ion cell is the combination of cathode, anode, electrolyte and separator materials. It defines the cell's voltage, energy per unit mass, power, service life, safety and cost, and it forces trade-offs among those properties.
- What is regenerative braking?
Regenerative braking uses the electric motor as a generator during deceleration: it converts part of the vehicle's kinetic energy into electricity that recharges the battery, and it reduces the work of the friction brakes.
- What is the battery management system?
The battery management system (BMS) is the electronics that monitors the cells of a pack, measures voltage, current and temperature, estimates its state, balances the cells and disconnects the battery if it operates outside safe limits.
- What is the communication mode between vehicle and charger?
The communication mode between vehicle and charger defines how they coordinate to charge safely. In the usual AC mode, the control pilot signal tells the vehicle the maximum available current and the connection status; for DC, digital communication is added.
- What is thermal runaway in lithium batteries and what causes it?
Thermal runaway is a chain reaction in which the heat generated inside a cell accelerates reactions that generate more heat; it is caused by internal short circuits, overcharging, mechanical damage, overheating and manufacturing defects.
- Why does a battery lose capacity with cycling?
A battery loses capacity with cycling because side reactions consume active lithium, the electrode material degrades, and lithium plating and mechanical stresses reduce the share of material that can exchange charge.
- Why does a charger suddenly stop charging?
A charger suddenly stops charging because a protection device tripped, temperature forced it to stop or reduce power, communication with the vehicle was lost, the vehicle asked to stop charging, or there was a grid disturbance.
- Why does a charging connector heat up?
A charging connector heats up through Joule heating in a high contact resistance, caused by wear, dirt, oxidation, poor insertion, loose terminals or a cable undersized for the current.
- Why does a vehicle’s range drop in the cold?
Range drops in the cold because the battery delivers less usable energy at a higher internal resistance, and because the vehicle spends more energy on cabin heating, on warming the battery and on overcoming denser air.