How are vehicle batteries reused in stationary storage?

Vehicle batteries are reused in stationary storage after assessing their condition, sorting modules of similar performance and reconfiguring them with a new management system, converter and protections, in applications that demand less power.

Why it makes technical sense

A vehicle demands high power, low weight and tough operating conditions from its battery. When the battery no longer meets those demands because of lost capacity or increased resistance, it still retains a considerable part of its capacity. In a stationary application, weight and volume matter less and charge and discharge rates are moderate, so it can remain in service.

Stages of the process

  1. Gathering history: data from the vehicle’s management system, if available, such as temperatures, cycles and events.
  2. Assessment: capacity, internal resistance, spread between cells, self-discharge and insulation are measured, and the physical condition is inspected.
  3. Sorting: modules or cells with similar behavior are grouped, because the elements of a series string are limited by the lowest capacity.
  4. Reconfiguration: new strings are built, with a new management system, protections, cooling and enclosure.
  5. Integration: they are connected to a power converter and to the control system, with the applicable grid protections.

Technical challenges

  • Heterogeneity: batteries of different chemistry, age and design do not mix easily.
  • Uncertainty about the real condition, because the history may be incomplete and internal damage is not always detected by external measurements.
  • Access to information from the original management system, which is sometimes closed.
  • Safety: a used battery may have a higher risk of internal failure, so it is tested and protected with care.

What to expect from the application

The most suitable applications call for gentle cycling, such as solar energy storage or backup. Those requiring high power rates or a large number of demanding cycles are more difficult.

When it does not apply

Not every battery is a candidate: one with physical damage, poor insulation or a cell with anomalous behavior is rejected. Handling and testing high-voltage packs is a job for qualified personnel, and the installation must comply with the applicable regulations.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.