What ventilation does
Ventilation replaces the air in the space with clean air. It works in two ways: it dilutes contaminants to acceptable levels and it displaces stale air toward an outlet. For it to work, fresh air must reach every zone, not just the entry opening. A space with corners, partitions or levels has dead zones where the air stagnates.
Supply or exhaust
- Supply (blowing): a fan pushes clean air through a duct to the work area. This is the usual way to provide air to people.
- Exhaust: a fan draws out contaminated air. It is preferred when the contaminant source is localized, such as welding fumes, and can be captured close to it.
- Combined: supply through one opening and exhaust through another to create a path that sweeps the volume.
Decisions that matter
Where the air is taken from
The fan intake must be in clean air, away from engine exhaust, stacks, process vapors or pits. Ventilating with contaminated air makes the problem worse.
Where it is directed
The supply duct is run to the occupied zone. If the contaminant is heavier than air, it is exhausted from low down; if it is lighter, from up high. There must be an outlet opening so that the air can circulate.
What equipment is used
If there is a risk of flammable gases or vapors, the fan and its power supply must be suitable for that atmosphere, so as not to introduce an ignition source. Flexible ducts must be free of kinks and tears.
What ventilation does not do
- It does not replace measurement. You ventilate and measure, and keep measuring while the work goes on.
- It does not eliminate a source that keeps generating contaminant, such as sludge that releases gas.
- It must not be done with pure oxygen, which creates a fire hazard.
How to interpret the result
After ventilating long enough to renew the volume, measurements should show acceptable conditions at all levels. If readings get worse again when the fan stops, the space is generating contaminant and requires continuous ventilation or respiratory protection. Entry and controls must be applied by trained people, in accordance with current regulations.
This guide is for information only. Work involving electrical hazards, heights or hazardous atmospheres must be carried out by qualified, authorized personnel in accordance with applicable regulations.