Technical guides
Clear explanations of concepts, methods, standards and measurements for engineers and technicians.
- Antennas 52
- Confined spaces 52
- Dielectric materials 54
- Dielectric oils 61
- Electric vehicles 52
- Electrical safety and PPE 52
- Electronic instrumentation 52
- EMC/EMI 53
- Environmental testing 53
- Grounding 54
- Industrial electrical systems 52
- Insulation and high voltage 61
- Metrology and calibration 59
- Oscilloscopes 53
- Power quality and Grid Code 61
- RF and microwave 61
- Solar energy 52
- Temperature and pressure 52
- Thermography 53
- Transformers 55
- Troubleshooting 52
- Vibration 52
- Wireless communications 52
- How do you measure the regulation of a power supply?
The regulation of a power supply is measured as the change in its output voltage when the load (load regulation) or the input voltage (line regulation) varies, always measuring at the output terminals.
- How do you measure the time interval between two events?
To measure the time interval between two events, connect each event to a channel of a counter or an oscilloscope, choose the edge and trigger level for each one, and measure the difference between the trigger instants.
- How do you measure the true RMS value of a distorted signal?
To measure the true RMS value of a distorted signal, you need a true RMS instrument with sufficient bandwidth and crest factor for the waveform.
- How Do You Plan a Power Quality Monitoring Campaign?
A power quality monitoring campaign is planned starting from the question it must answer: define the objective, measurement point, parameters, evaluation criterion and a duration that covers all representative operating modes.
- How Do You Prepare an Installation for a Load Expansion?
To expand the load, you must confirm with measured data that every element in the supply chain has enough capacity: transformer, conductors, busbars, protective devices and short-circuit levels, not just the main breaker.
- How Do You Prepare an Insulation Resistance Test on Energizable Equipment?
To prepare an insulation resistance test, de-energize, verify the absence of voltage, isolate the equipment from other circuits, clean it and record the conditions before applying the test voltage.
- How do you reduce noise in a low-level signal measurement?
To reduce noise in a low-level signal measurement, you work on three fronts: keeping noise from getting in, lowering the measurement bandwidth, and averaging whatever gets through anyway.
- How Do You Safely Discharge Equipment After an Insulation Test?
After an insulation test, the equipment retains charge in its capacitance, so it is discharged in a controlled way and kept grounded for a time before it is handled.
- How do you safely measure a power signal with an oscilloscope?
Use a probe suited to the voltage and the measurement category, normally a differential probe, with the oscilloscope properly grounded and without ever defeating the protective connection, and have the work done by qualified personnel.
- How Do You Select the Connection Point for a Power Analyzer?
The connection point of an analyzer is chosen according to the question to be answered: at the service entrance to evaluate compliance, at the sensitive load to see its effects, and at the suspect load to isolate its contribution.
- How do you set an analyzer’s thresholds to capture voltage events?
An analyzer's thresholds for capturing voltage events are set relative to the declared nominal voltage, with values for sags, overvoltages and interruptions, hysteresis to prevent repeated triggering, and a recording time before and after the event.
- How do you set up a pulse width trigger?
A pulse width trigger makes the oscilloscope capture only when a pulse lasts less than, more than or exactly a defined time, which makes it possible to isolate defective pulses among many correct ones.
- How Do You Size a Capacitor Bank Without Amplifying Harmonics?
A capacitor bank is sized by calculating the kvar needed to bring the power factor to the target value and checking that its resonant frequency with the network stays well away from the harmonics present; if it does not, detuning reactors are used.
- How Do You Take an Oil Sample Without Contaminating It?
A representative oil sample is taken with clean, dry containers, purging the sampling valve beforehand, avoiding contact with air and moisture, and recording the condition of the equipment; any contamination distorts the diagnosis.
- How do you trace the origin of a voltage sag: upstream or downstream?
Whether a voltage sag originates upstream or downstream of the measurement point is inferred by comparing the sag with the behavior of the current: if more current flows toward the load during the event, the fault is downstream; if the current drops or does not rise, it is upstream.
- How do you use a mask test on an oscilloscope?
A mask test defines forbidden regions around a waveform or eye diagram and has the oscilloscope acquire many waveforms, counting how many violate the mask to give a pass or fail result.
- How do you use the average function to reduce noise?
The average function sums many acquisitions of a repetitive signal and calculates their mean; uncorrelated random noise is reduced, and the signal that repeats on every trigger remains.
- How do you verify a multimeter between calibrations?
A multimeter is verified between calibrations by using it to measure known stable standards, such as a voltage reference and precision resistors, and comparing against limits defined in advance, without this replacing calibration.
- How do you work in a tank with an inert atmosphere?
In a tank with an inert atmosphere there is not enough oxygen to breathe, so entry is made only with independent supplied air, under a special permit, with an attendant and rescue prepared, and without relying on ordinary oxygen detectors for breathing.
- How do you work in an underground cable vault?
Working in an underground cable vault requires treating it both as a confined space and as an electrical installation: check the atmosphere, control water and access, and make sure that the circuits are de-energized or that the work is done by qualified personnel.
- How do you work safely on a vehicle’s high-voltage system?
Working safely on a vehicle's high-voltage system means that only qualified, trained personnel intervene, following the manufacturer's procedure, with verified de-energization, lockout, suitable protective equipment and insulated tools.
- How does a battery electric vehicle work?
A battery electric vehicle stores energy in a battery pack, converts it into three-phase alternating current with a traction inverter and drives the wheels with an electric motor. It has no combustion engine or fuel tank.
- How does a catalytic combustible gas sensor work?
A catalytic combustible gas sensor contains two hot elements in a Wheatstone bridge: the gas burns on the active element, whose temperature rises and resistance changes, and that difference from the reference element is the signal proportional to the concentration.
- How Does a Circuit Breaker Electronic Trip Unit Work?
An electronic trip unit measures current with sensors, calculates its RMS value in a microprocessor and commands the breaker to open according to configurable protection curves for overload, short circuit and ground fault.
- How does a clamp-on ground tester work?
A clamp-on ground tester induces a voltage in a closed loop with one core, measures the resulting current with another and calculates the loop resistance, with no need to drive probes.
- How does a condenser bushing work?
A condenser bushing distributes electrical stress through concentric conductive layers inside the insulation, forming capacitors in series that maintain a controlled voltage gradient from the conductor to the flange.
- How does a cooled-core thermal camera work?
A cooled-core camera uses a photon detector chilled to a very low temperature to eliminate its own thermal noise, which gives it high sensitivity and very short exposures.
- How does a current probe work?
A current probe measures the magnetic field produced by the current in a conductor and delivers a proportional voltage, without interrupting the circuit, combining a Hall sensor for DC and low frequency with a transformer for the AC part.
- How does a digital multimeter work?
A digital multimeter works by conditioning the input quantity into a DC voltage within the range of an analog-to-digital converter, which turns it into a number shown on the display.
- How Does a Directional Coupler Work?
It is a four-port component that takes a known fraction of the signal traveling in one direction and delivers it to a coupled port, while almost none of the signal traveling in the opposite direction reaches that port.