What is being tuned
A cavity filter is made up of resonators coupled to one another. Each resonator has its own frequency, which is changed with a tuning screw, and between neighboring resonators there is a coupling, normally adjustable. The center frequency and bandwidth depend on both sets of adjustments, and these influence each other, so tuning is an iterative process.
What to display on screen
- Return loss (S11). It shows the match. In a well-tuned filter, several reflection minima appear within the passband, one for each resonator.
- Transmission (S21). It shows the passband, the out-of-band rejection and the insertion loss.
Reflection is more sensitive to fine adjustment than transmission, so it is used as the main guide.
General sequence
- Calibrate the analyzer at the plane of the filter connectors, with a span wider than the band.
- Detune the resonators to start from a known condition.
- Tune each resonator one at a time, looking for its resonance, with the help of a reflection or phase view.
- Adjust the couplings to give the passband the desired width and symmetry.
- Repeat the cycle, because each change affects the others, and reduce the span for fine adjustment.
- Tighten the locknuts and measure again, because tightening them usually changes the tuning.
An alternative technique
With a time-domain measurement, the response of each resonator is observed separately and they are tuned in order starting from the input port, which makes it easier to identify which screw corresponds to each peak.
What to consider
- Metal tools near the cavity disturb the field; dielectric tools are preferred.
- Temperature changes the dimensions and shifts the response, so it is advisable to tune with the filter stabilized.
- A filter that operates at high power must be verified under its operating condition.