The balance that decides everything
A resistor converts the electrical energy it receives into heat. Its temperature stabilizes when the heat it dissipates equals the heat it gives off to the environment. It burns out when that balance is only reached at a temperature the material cannot withstand. The power dissipated depends on the square of the current, or the square of the voltage divided by the resistance, so small increases in current produce larger increases in heating.
Common causes
- Current higher than the design value: a downstream short circuit, a load that increased or a failure of another component.
- Insufficient cooling: poor ventilation, mounting tight against other parts, dust buildup or a hot environment. The power rating refers to specific mounting and ambient temperature conditions.
- Selection with little margin: operating continuously near the power rating accelerates aging.
- Energy pulses: a resistor can withstand the average power and fail from short, high-energy pulses, such as those from capacitor charging or braking.
- Changed resistance value: if its value drops, at constant voltage the power increases.
- Poor connection: a loose terminal heats up locally.
What an engineer sees in practice
You find blackened parts, with cracked coating and sometimes an open circuit. The area of the board under the resistor may show charring. These signs indicate that it suffered heat, but not why.
How to tell the cause from the victim
- Calculate the power it should dissipate in the real circuit and compare it with its rating.
- Check the components that set the current: semiconductors, capacitors, loads.
- Check the airflow and mounting.
- When replacing it, measure the temperature in operation to confirm the margin.
Replacing the resistor with an identical one without finding the cause usually repeats the failure. Checks on energized equipment must be carried out by qualified personnel in accordance with applicable regulations.