Why does a product fail from vibration at resonance?

At resonance, a structure amplifies the input vibration because the excitation frequency matches a natural frequency and damping is low, which raises stresses and accelerates fatigue.

The principle

Every structure has natural frequencies at which it oscillates easily. If external vibration excites one of them, the response grows far beyond the input. The ratio of response to excitation at resonance depends on damping: the less damping the structure has, the greater the amplification.

Why that breaks things

Fatigue depends on the stresses repeated in each cycle. At resonance, the amplitude of motion and deformation increases, and with it the stresses in critical areas: weld roots, component leads, screws, brackets and board edges. A small input force accumulates damage quickly if it occurs at the wrong frequency.

What you see

  • A component that always detaches or fractures in the same area.
  • A connector or solder joint with intermittent failures during vibration.
  • A measured response with a clear peak in the spectrum.
  • A shift in the resonant frequency after the test, which indicates loosening or accumulated damage.

How it is identified

A low-amplitude sweep is used to measure the transfer function between the input and the response at points on the product. The peaks mark the natural frequencies. The mode shape, observed with accelerometers or optical techniques, then shows which part moves the most.

How it is corrected

There are several strategies: raising the natural frequency above the excited band by increasing stiffness or reducing mass; adding more attachment points; adding damping with viscoelastic materials; or using isolation to separate the product from the source. Every change modifies mass and stiffness, so it must be verified with another sweep.

An important nuance

The product’s resonance does not always coincide with that of the fixture. A poorly designed fixture can introduce amplifications that will not exist in service. That is why the response is compared with and without the product and the control is verified. The worst case in service can arise when the resonance coincides with the dominant frequency of the source, such as a motor.