Why does a power transistor fail?

A power transistor fails from excessive junction temperature, overvoltage, overcurrent, avalanche or faulty switching, and the cause almost always lies in the surrounding circuit rather than in the device itself.

A device that lives close to its limits

Power transistors, such as MOSFETs, IGBTs and bipolars, handle high voltages and currents and dissipate power as heat. They have safe operating limits: voltage, current, junction temperature and energy. Exceeding them, even for an instant, can damage them.

Common failure mechanisms

  • Overtemperature: insufficient heat dissipation or ventilation, degraded thermal paste or poor heat sink mounting raise the junction temperature and accelerate aging.
  • Overvoltage: spikes generated by parasitic inductances when turning off high currents, or transients from the grid, can exceed the blocking voltage and cause avalanche.
  • Overcurrent and short circuit: a shorted load or a stalled motor raises the current beyond what the device can withstand, and the protection does not act in time.
  • Faulty gate drive: insufficient gate voltage leaves the device in the linear region, where it dissipates a lot of power; excessive voltage damages the gate oxide.
  • Poor switching: insufficient dead time in a bridge allows two devices in the same leg to conduct at the same time, causing a momentary short circuit.
  • Thermal fatigue: repeated heating and cooling cycles fatigue the internal bonds over time.

What an engineer sees in practice

The device is often found shorted between its power terminals. That is the result, not the cause. What reveals the cause is the surroundings: the condition of the gate driver, protections, snubbers, bus capacitors, heat marks on the heat sink and the connected load.

How to guide the analysis

  1. Look at the physical damage: cracks, holes in the package, discoloration.
  2. Check the drive and protection circuits before replacing.
  3. Verify the thermal mounting and ventilation.
  4. Measure the voltage and current switching waveforms with the equipment already repaired.

This work involves electrical risk; it must be carried out by qualified personnel in accordance with applicable regulations.