A shield is an enclosure, not a sheet
A continuous metal wall provides high attenuation. A real enclosure has seams between panels, covers, ventilation, display windows, connectors and cable holes. Each of these discontinuities interrupts the currents flowing on the surface and lets energy through. The effectiveness of the whole is set by the weakest aperture.
How an aperture acts
Currents induced in the enclosure wall flow on the surface. A slot that cuts them behaves like a slot antenna: the field redistributes and radiates through it. When the largest dimension of the slot is an appreciable fraction of the wavelength, around one half, transmission is high. Below that dimension the leakage falls progressively, and the largest dimension determines the result more than the area does.
Practical consequences
- A long seam between two poorly joined panels can leak more than a large round hole.
- Many small holes, such as a perforated mesh, provide ventilation with less leakage than one long slot.
- Leakage increases with frequency, because the wavelength gets shorter and any aperture becomes relatively larger.
- Cables passing through the wall carry disturbances inside or outside and cancel the benefit of a closed enclosure.
Techniques for controlling apertures
- Conductive gaskets or contact fingers on seams and covers, with clean metal surfaces.
- Screws or bonding points at short intervals relative to the wavelength of the highest frequency of interest.
- Ventilation through metal honeycomb panels, whose channels act as waveguides below their cutoff frequency.
- Windows with conductive glass or fine mesh.
- Filters or shielded connectors on every cable crossing the wall.
How to interpret a problem
If the emission changes when you tighten screws, remove a cover or cover a slot with conductive tape, the aperture is part of the path. This quick test helps decide where to reinforce before redesigning.