Why a complex number
Under alternating current, the polarization of a material does not always follow the field without delay. That response is represented by a complex quantity: the real part describes the component in phase with the field, and the imaginary part the out-of-phase component that corresponds to losses. It is a compact way of bringing two phenomena together in a single function of frequency.
What each part means
- Real part: this is the relative permittivity usually called the dielectric constant. It indicates how much energy is stored in the material compared with vacuum.
- Imaginary part: this is the loss factor. It represents the energy converted into heat by conduction and relaxation.
The ratio of the imaginary part to the real part is the loss tangent.
Frequency and temperature dependence
The two parts are not independent: they are linked by causality relations known as Kramers-Kronig relations. Where the real part falls with frequency, the imaginary part shows a maximum. This pair of behaviors is the signature of a relaxation mechanism. For this reason, speaking of “the dielectric constant” of a material without stating frequency and temperature is incomplete.
Why it matters at RF
In antennas, transmission lines, filters and high-frequency circuit substrates, the real part sets the propagation velocity and the dimensions of the elements, and the imaginary part sets the attenuation. An error in permittivity translates into a shift in resonant frequency; a higher loss than expected lowers efficiency.
How it is measured
Depending on the frequency, capacitance bridges with electrodes, transmission lines, resonant cavities or open-ended coaxial probes are used. Each technique has a range of frequencies and losses for which it is suitable. Sample preparation, including flatness, thickness and electrode contact, is an important source of uncertainty.
How to interpret the result
Values are reported with their frequency, temperature and technique. Anisotropic materials, such as fiber laminates, can have different values depending on the field direction. They also change with moisture, so the sample condition must be recorded.