What is the difference between conducted and radiated emissions?

Conducted emission is the disturbance that equipment injects into its cables, above all into the power network, and it is measured at low frequencies with a stabilization network; radiated emission is what leaves through the air as a field and is measured with an antenna.

The essential difference

Both are disturbances generated by the same equipment, but they travel by different paths. Conducted emission flows as current or voltage along the conductors connected to the equipment: mains cable, signal lines and control lines. Radiated emission propagates through space as an electromagnetic field, emitted by circuits, traces, enclosures and, very often, by the cables themselves acting as antennas.

How each one is measured

Aspect Conducted Radiated
Path Cables Air
Instrument Receiver with line impedance stabilization network Receiver with calibrated antenna
Quantity Voltage at the port Field strength
Environment Reference plane and network Chamber or open-area site

The stabilization network presents a defined impedance to the network and isolates the equipment from noise on the power network, so that the measurement is repeatable.

Frequency regions

Conducted emission is monitored in the lowest frequency range, where cables are short compared with the wavelength and do not radiate well. At higher frequencies cables do radiate, and control shifts to the field. In practice, a low-frequency conducted disturbance can become radiated if common-mode current flows along a long cable.

Common mode and differential mode

  • In differential mode, the current travels along one conductor and returns along the other. It is usually caused by power supply switching.
  • In common mode, the current flows along all conductors in the same direction and returns through ground or through space. It is the main cause of radiation from cables.

How they are reduced

  1. Line filters with common-mode chokes and suitable capacitors.
  2. Control of switching times and of the area of current loops.
  3. Shielding and good bonding of the enclosure and cable braids.

What the engineer sees

Each type of emission is compared with its own limits. Equipment can pass one and fail the other, and the solutions are not interchangeable.