What is the cutoff frequency of a waveguide?

The cutoff frequency of a waveguide is the minimum frequency at which a mode can propagate through it; below it, the field decays exponentially and carries no power. In a rectangular guide with the dominant mode, it depends on the larger dimension of the cross-section.

Why a cutoff exists

In a hollow metal waveguide, the wave propagates by bouncing between the walls. For that pattern to be consistent with the boundary conditions, the field must fit the dimensions of the cross-section. Each mode has a minimum frequency below which this fit is not possible. Below it, the propagation constant is purely real, the field attenuates exponentially with distance and the power is reflected rather than transported. The guide then acts as a high-pass filter.

The cutoff frequency of the dominant mode

In a rectangular guide, the mode with the lowest cutoff frequency is the one with a single field variation along the larger dimension. Its cutoff frequency equals the speed of light divided by twice the larger dimension of the cross-section, if the guide is air-filled. If it is filled with a dielectric, the speed is reduced by the square root of the relative permittivity and the cutoff frequency falls. For guides of other shapes, the value depends on the geometry and the mode.

Consequences

  • Dispersion: the phase velocity in a guide is greater than the speed of light, and the group velocity, which is that of energy and information, is lower. Both depend on frequency, so wideband signals are distorted.
  • Guide wavelength: it is longer than in free space and grows markedly near cutoff. Elements whose length depends on the wavelength, such as cavities and matching sections, are sized with it.
  • Attenuation: near cutoff, the guide is inefficient and the loss increases.
  • Useful band: operation is above the cutoff of the dominant mode and below the cutoff of the next mode, so that only one mode propagates. With several modes, the signal is distorted and measurements lose their meaning.

What an engineer sees in practice

When a guide is measured with a network analyzer, transmission falls sharply below cutoff and stabilizes above it. This is useful for verifying dimensions: a cross-section different from the expected one shifts the cutoff. A guide below cutoff is also used as a precision attenuator or as a block for low frequencies.

An example

If one guide is twice as wide as another, its cutoff frequency is half. This is why higher frequency bands use smaller guides, with more demanding mechanical tolerances.