What Is the Dielectric Strength of an Insulator?

Dielectric strength is the maximum electric field an insulator withstands before it loses its insulating capability and conducts; it is expressed as voltage per unit of thickness and is not a fixed constant of the material.

Definition

An insulator withstands an electric field up to a certain limit. If that limit is exceeded, the material suddenly becomes conductive, which is called dielectric breakdown. Dielectric strength is the field value at which this happens, and it is expressed as voltage divided by thickness, for example in kilovolts per millimeter.

Strength and breakdown voltage

They are not the same. Breakdown voltage is the voltage at which a specific sample fails; strength is that voltage referred to the thickness. Even so, doubling the thickness does not double the voltage withstood: in real insulators the effective strength tends to fall as the thickness or the stressed volume increases, because a defect is more likely to be present.

What changes it

  • Impurities and moisture: particles, bubbles or water create weak points; in oil, moisture and particles greatly reduce the breakdown voltage.
  • Voids and defects: in solids, gas-filled cavities discharge before the material does and erode it.
  • Temperature: in general, heating reduces the strength.
  • Voltage waveform and duration: insulation can withstand more under a short impulse than under a sustained voltage; voltage applied for a long time causes aging.
  • Electrode geometry: a non-uniform field concentrates the stress at points and edges and reduces the failure voltage.
  • Gas pressure and composition, in gaseous insulation.

How it is measured

A sample is placed between electrodes of standardized geometry and the voltage is raised along a defined ramp until breakdown occurs. Results are scattered, so several repetitions are performed and the set is analyzed. In insulating oil, the breakdown voltage test is commonly used as an indicator of contamination, though not of other forms of chemical degradation.

How to interpret the result

A laboratory value from a small sample is not the operating limit of the equipment. Design applies margins because real equipment has more complex geometries, aging and overvoltages. A low value in oil signals contamination and the need to treat or replace it.

Warning: dielectric tests involve high voltage and must be performed by qualified personnel, in accordance with applicable regulations and safety procedures.