24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

What is the arc resistance of an insulating material?

Arc resistance is the ability of an insulator's surface to withstand an electric arc without becoming conductive; it is expressed as the time the arc takes to form a conductive path across it.

Definition

When an electric arc touches the surface of an insulator, the energy heats and decomposes the material. If a conductive residue such as carbon remains, the arc finds an easier path and the surface stops insulating. Arc resistance measures how long the material holds out before that happens.

Why materials differ

Organic polymers carbonize as they decompose, and carbon conducts. Inorganic materials, such as ceramics or glasses, do not form that conductive residue and withstand arcing better. Some polymers decompose into gases and leave little carbon, and others contain mineral fillers that absorb heat or release gases that extinguish the arc.

What distinguishes it from other properties

  • Dielectric strength: the voltage at which the material is punctured through its thickness. It is not the same as arc resistance.
  • Tracking resistance: the ability to resist the formation of conductive paths under voltage in the presence of moist contamination. It is a related phenomenon, but with a different cause.
  • Surface resistance: a measure of conduction across the surface at low voltage.

A material can be good in one and poor in another.

How it is evaluated

The test applies arcs of increasing intensity in stages to the sample surface, with defined electrodes, and records the time until a conductive path appears or the material ignites. The result is compared against a scale. Details such as the application schedule depend on the method and on the current edition of the standard used.

What influences it

Composition, filler and additive content, surface contamination and humidity all change the result. So do the electrode geometry and the condition of the surface. That is why comparison requires the same method.

Why it matters

In switches, contactors, fuse holders and appliance insulators, arcs are a part of normal operation. Choosing a material with good arc resistance helps preserve the insulation over the life of the device.

Notice

The arcs and voltages involved are dangerous. Tests and any work on electrical equipment must be carried out by qualified personnel following the applicable safety regulations.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer