Why an amplifier compresses
An amplifier is linear only for small signals. As the input level increases, the active devices approach the limits imposed by the power supply and by their characteristic, and the output stops growing in proportion. The gain, which was constant, begins to decrease. This behavior is called compression.
Definition of the 1 dB compression point
It is the power level at which the gain is one decibel lower than the small-signal gain. It can be expressed in two ways:
- Input-referred. The input power that causes one decibel of compression.
- Output-referred. The output power at that point.
The two are related by the gain: the output power at compression is the input power plus the linear gain, minus one decibel. It is essential to state which one a figure refers to, because they differ by the value of the gain.
How it is measured
A fixed-frequency signal is applied and its input power is swept while the output is measured with a power meter or an analyzer. Gain is plotted against power to find where it falls by one decibel. On a network analyzer with a power sweep function, the curve is obtained directly. It is important that the amplifier be under the specified bias conditions and that the measuring instrument itself not saturate.
What it means in practice
- Near compression, signals of varying amplitude are distorted; with amplitude-varying modulations, distortion appears and the spectrum widens.
- Together with intermodulation, it defines the maximum useful output level for linear operation.
- Beyond this point, the output approaches a limit called saturation power.
When it is not enough
One-decibel compression describes a single signal. With several simultaneous signals, intermodulation distortion can become a limit before compression is reached. Measurement with pulses or with heating can give values different from those obtained with a continuous wave.