24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

Technical guides

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • Phase or Amplitude Modulation: What Is the Trade-Off?

    Modulating phase is more robust against amplitude noise and keeps power constant, while adding amplitude allows more bits per symbol to be transmitted, at the cost of requiring greater linearity and a better signal-to-noise ratio.

  • Piezoresistive or capacitive pressure sensor?

    A piezoresistive sensor measures diaphragm deformation with gauges whose resistance changes, and a capacitive sensor with the change in capacitance between diaphragm and plate; the former is rugged and general-purpose, and the latter stands out at low and differential pressures.

  • Polymer or ceramic as an electrical insulator?

    Polymers usually win on processability, toughness and low weight, and ceramics on thermal stability, hardness and resistance to arcing and weathering; the choice depends on temperature, mechanical stress, shape and manufacturing cost.

  • Portable analyzer or fixed meter: when is each one the right choice?

    A portable analyzer is the right choice for investigating a problem, measuring at several points for limited periods or supporting a diagnosis; a fixed meter is the right choice when continuous monitoring, history and ongoing compliance are needed at a defined point.

  • Pre-compliance testing or certification testing?

    Pre-compliance tests are exploratory, are carried out during development with simpler instruments, and aim to find and correct problems; certification tests are formal, performed at a validated site with calibrated instruments, and produce the report that supports the declaration of conformity.

  • Qualitative or quantitative thermography?

    Qualitative thermography looks for patterns and differences between components without assigning a reliable absolute value, while quantitative thermography measures temperatures with controlled emissivity and conditions so they can be compared with criteria or limits.

  • Repair or replace failed equipment?

    Repair when the cause of the failure is understood, the equipment can return to safe and reliable performance, and the total cost is reasonable given its remaining service life; replace when any of those conditions is not met.

  • Rigid or flexible substrate for high-frequency circuits?

    A rigid substrate offers better dimensional stability, impedance control and heat dissipation, while a flexible one can be folded and integrated into curved geometries, at the cost of greater sensitivity to deformation and moisture at high frequency.

  • RTD or thermocouple for a process?

    The choice depends on the temperature range, accuracy, response time and mechanical conditions: the RTD usually wins on accuracy and stability, and the thermocouple on range, ruggedness and speed.

  • Sample rate: how it relates to bandwidth

    The sample rate must be several times higher than the oscilloscope's bandwidth. The theoretical minimum is twice the highest frequency in the signal, but real waveform reconstruction requires a larger margin.

  • Semi-anechoic chamber or open-area test site?

    A semi-anechoic chamber controls the environment and allows testing at any hour and in any weather, at the cost of installation and absorbers; an open-area test site avoids the limitations of walls but depends on ambient noise and weather. Both are acceptable if validated for the frequency range.

  • Shielding, filtering or separation: which works best for each problem?

    It depends on how the disturbance couples: shielding addresses field coupling into or out of the enclosure, filtering acts on what travels along the cables, and separation reduces coupling between nearby circuits. The choice is based on the path identified, not on the tool at hand.

  • Short-Range or Long-Range Low-Power Wireless Communication?

    Short-range communication offers higher speed and lower latency over short distances, while long-range low-power communication sacrifices speed to reach far with very little consumption; the choice depends on distance, data volume and power supply.

  • Silicone oil or mineral oil as an insulating fluid?

    Silicone oil offers a high flash point and good thermal stability, so it is chosen where fire risk carries the most weight; mineral oil is more economical, has lower viscosity, and is backed by more experience and diagnostic knowledge.

  • Single ground or separate grounds for each system?

    Within one installation, a single grounding system is advisable or, if there are several electrodes, they should be interconnected with low impedance; separate grounds with no connection create dangerous potential differences during faults and lightning.

  • Sinusoidal or random vibration?

    Sinusoidal vibration excites one frequency at a time, which is ideal for finding resonances; random vibration excites all of them at once with a defined spectral density and more closely resembles a real environment.

  • Slow charging or fast charging?

    Slow AC charging is suitable when the vehicle is parked for many hours and a lower installation cost is sought, and fast DC charging when the stop is short, in exchange for higher power and greater thermal demands.

  • Solar tracker or fixed structure?

    A solar tracker moves the modules to keep them facing the sun and captures more energy than a fixed structure, at the price of mechanisms, controls, maintenance and space requirements. The gain depends on the site.

  • Solidly Grounded or Resistance Grounded System?

    The difference lies in how much ground-fault current is allowed: with solid grounding the current is very high and the fault is cleared immediately; with a resistor it is deliberately limited to reduce damage and, in some schemes, to keep operating.

  • Spectrum Analyzer or Network Analyzer: What Does Each One Measure?

    A spectrum analyzer measures which signals are present at its input and their amplitude at each frequency; a network analyzer measures how a device transforms a signal that the analyzer itself generates, with magnitude and phase.

  • Stacked core or wound core?

    A stacked core is assembled from cut laminations interleaved at the joints; a wound core is formed from a continuous steel strip, which reduces joints and losses but limits size and ease of assembly with the coils.

  • Stud, adhesive or magnet mounting?

    A stud gives the stiffest attachment and the widest frequency band, adhesive is a good alternative when drilling is not possible, and a magnet is the most practical option but limits the usable range at high frequencies.

  • Thermography or ultrasound to detect loose connections?

    They complement each other: thermography detects the heating produced by a high-resistance connection under load, and ultrasound detects the noise of discharges or arcs, so each technique sees a different phenomenon.

  • Two-wire or four-wire measurement

    Two-wire measurement includes the resistance of the leads and contacts in the result; four-wire measurement eliminates it by separating the conductors that carry the current from those that measure the voltage. It matters above all with low resistances.

  • Type N, SMA or precision connector: which to choose for your application

    The choice between a type N, SMA or precision connector depends on the maximum frequency, the repeatability required, the power, the size and the number of connections: type N is rugged and general purpose, SMA is compact, and precision connectors are chosen when measurement accuracy matters.

  • Unidirectional or bidirectional charging?

    Unidirectional charging only delivers energy from the grid to the vehicle; bidirectional charging also allows it to be returned, which requires reversible power electronics, grid synchronization, and additional communication and protection.

  • Vertical rod or horizontal electrode?

    It depends on how soil resistivity changes with depth: the vertical rod wins when the deep layers conduct better, and the horizontal electrode wins when the surface layer does.

  • What a cold operation test is

    A cold operation test verifies that equipment starts and operates correctly while subjected to low temperature, unlike cold storage, where the only check is that it survives.

  • What an accelerated life test is

    An accelerated life test subjects a product to stresses higher than those of normal use to trigger, in a short time, the same failure mechanisms that would occur over years, and from that to estimate its life under normal conditions.

  • What an environmental test profile is

    An environmental test profile is the time-defined sequence of conditions applied to a sample, such as temperature, humidity and vibration, with their values, rates of change and durations.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer