Technical guides
Clear explanations of concepts, methods, standards and measurements for engineers and technicians.
- Antennas 52
- Confined spaces 52
- Dielectric materials 54
- Dielectric oils 61
- Electric vehicles 52
- Electrical safety and PPE 52
- Electronic instrumentation 52
- EMC/EMI 53
- Environmental testing 53
- Grounding 54
- Industrial electrical systems 52
- Insulation and high voltage 61
- Metrology and calibration 59
- Oscilloscopes 53
- Power quality and Grid Code 61
- RF and microwave 61
- Solar energy 52
- Temperature and pressure 52
- Thermography 53
- Transformers 55
- Troubleshooting 52
- Vibration 52
- Wireless communications 52
- What are a failure mode and its effect?
The failure mode is the way in which a component or function stops fulfilling its purpose; the effect is the consequence of that failure for the system and for the person using it.
- What Are a Ferrite Circulator and Isolator?
They are non-reciprocal three-port devices that use magnetized ferrite to make the signal circulate in only one direction from port to port; an isolator is a circulator with one port terminated in a load, which passes the signal in one direction and absorbs the reverse signal.
- What Are a Primary Standard and a Secondary Standard?
A primary standard is one established with a method of the highest metrological quality without depending on another standard of the same quantity; a secondary standard receives its value by comparison with a primary one.
- What are absolute, gauge and differential pressure?
The three differ in the reference they are measured against: absolute pressure is measured against a perfect vacuum, gauge pressure against local atmospheric pressure and differential pressure between any two process pressures.
- What are common mode and differential mode?
In differential mode, the disturbance current travels along one conductor and returns along the other, in opposite directions; in common mode, it flows in the same direction along both conductors and returns through ground or the surroundings. Telling them apart determines which filter and which correction will work.
- What Are Creepage Distance and Clearance?
Creepage distance is the shortest path along the surface of the insulator between two conductive parts; clearance is the shortest path through the air. The first controls tracking and the second controls sparkover.
- What Are Displacement Power Factor and True Power Factor?
Displacement power factor is the cosine of the angle between the fundamental voltage and current; true power factor is the ratio of active power to total apparent power, and it includes the effect of harmonics.
- What are interchangeable lenses in thermography?
They are optics of different focal lengths mounted on the same thermal imaging camera to change the field of view and the minimum object size that can be measured accurately.
- What are interharmonics and where do they come from?
Interharmonics are voltage or current components whose frequency is not an integer multiple of the fundamental frequency; they come from loads whose current varies out of synchronism with the network, such as frequency converters, arc furnaces and modulated drives.
- What are natural frequency and resonance?
The natural frequency is the frequency at which a structure oscillates freely after an impulse, and resonance occurs when a periodic force excites it at that frequency, so that the vibration is amplified significantly.
- What Are No-Load and Load Losses in a Transformer?
No-load losses are those of the core and exist whenever the transformer is energized, almost regardless of the load; load losses are those of the windings plus stray losses, and they grow with the square of the current.
- What are S-parameters?
They are the coefficients that describe how a device with one or more ports reflects and transmits incident waves; each parameter is the complex ratio between a wave leaving one port and a wave entering another.
- What are sidebands in a spectrum?
They are peaks that appear on either side of a center frequency, separated from it by a modulating frequency, and they reveal that this component is being amplitude-modulated by another repetitive phenomenon.
- What are step voltage and touch voltage?
Step voltage is the potential difference between the two feet of a person standing on the ground; touch voltage is the one that appears between a structure touched by hand and the feet.
- What Are Systematic and Random Error?
Systematic error is the component of error that remains constant or varies predictably when a measurement is repeated, and it can be corrected if known; random error varies unpredictably and is reduced by averaging.
- What are the standard test conditions of a module?
Standard test conditions (STC) are the set of reference conditions under which a module's power is declared: an irradiance of 1000 W/m², a cell temperature of 25 °C and an air mass 1.5 solar spectrum.
- What are the state of charge and state of health of a battery?
State of charge (SOC) indicates how much charge remains in a battery relative to its current capacity. State of health (SOH) indicates how much it has deteriorated compared with a new battery, normally through loss of capacity or increased internal resistance.
- What are thermal level and range?
They are the two settings that determine which temperature interval is spread across the colors of the image: the range or span is the width of the interval, and the level is the central point around which it is placed.
- What are unconditional amplifier stability and the K factor?
An amplifier is unconditionally stable when it does not oscillate with any passive source or load impedance at a given frequency; the Rollett criterion verifies this with a K factor greater than one together with an S-parameter determinant of magnitude less than one.
- What are vertical resolution and effective bits?
Vertical resolution is the number of levels into which the oscilloscope's converter divides the voltage scale, according to its bits. Effective bits indicate how many of those bits are actually useful once noise and distortion are taken into account.
- What causes a circuit board to delaminate after humidity exposure?
Delamination occurs because the laminate absorbs moisture and, when it is heated, steam and stresses separate the layers, especially if the bond between resin and reinforcement was already weak.
- What Causes a Fuse to Open Without an Evident Fault?
A fuse opens without an evident fault because its element has fatigued from repeated heating, has seen a current peak higher than its curve tolerates, has run hot because of a poor connection, or is not the right type for the load.
- What causes a pressure gauge to stick under pulsation
Pulsation fatigues the mechanism and causes wear, play and an unstable or stuck pointer. A damper or a fill fluid reduces the effect, but neither replaces choosing the right gauge.
- What Causes a Trip from Gas Accumulated in the Relay?
The gas relay trips when gas accumulates in the conservator pipework, either because an internal fault is breaking down the oil or the insulation, or because air has entered the system; gas analysis distinguishes between the two cases.
- What causes an instrument to go out of tolerance between calibrations?
An instrument goes out of tolerance between calibrations because of component drift, damage from impacts or overloads, adverse ambient and operating conditions, contamination, wear or improper intervention. Periodic calibration is what detects it.
- What causes an instrument’s reading to drift as it warms up?
Thermal drift occurs because the instrument's components, such as the voltage reference, resistors and amplifiers, change their properties with temperature, and on power-up the instrument goes from a cold state to internal thermal equilibrium.
- What causes an insulation fault on the high-voltage bus?
An insulation fault on the high-voltage bus is usually due to moisture or condensation, coolant leaks, insulation damaged by abrasion or heat, contamination in connectors, or deterioration of the motor winding.
- What causes an oscilloscope not to trigger stably?
Unstable triggering occurs because the instrument does not always find the same condition in the signal: the level is outside the signal, the source or coupling is not appropriate, noise causes multiple crossings, or the signal has several similar events per period.
- What Causes Cable Failure from Electrical Treeing?
An electrical tree forms through repeated partial discharges at a high-field point in polymeric insulation, which carve out branching channels until one crosses the material and causes the failure.
- What causes carbonization of an insulator surface?
Surface carbonization of an insulator is caused by the localized heat of small discharges or arcs on the surface, which decomposes the organic polymer and leaves carbon, a conductive residue that facilitates further discharges.