Sinusoidal or random vibration?

Sinusoidal vibration excites one frequency at a time, which is ideal for finding resonances; random vibration excites all of them at once with a defined spectral density and more closely resembles a real environment.

How they differ

In sinusoidal vibration the shaker moves the table at a single frequency at any instant. That frequency can be swept across a range or held fixed. In random vibration, all the frequencies in a band are excited simultaneously, and the signal is described statistically by an acceleration spectral density, not by a specific waveform.

What sinusoidal testing provides

A low-amplitude sweep makes it possible to measure the resonant frequencies, the amplification factor and the damping of the structure. A more severe sweep or a dwell at resonance makes it possible to study fatigue. It is very useful in diagnostics and also when the real environment has periodic components, such as a motor rotating at a fixed speed.

What random testing provides

Real transport, vehicle and aircraft environments are broadband. Random vibration excites all the modes of the structure at once and better reproduces the accumulation of fatigue damage. Levels are specified with a spectral density as a function of frequency and with an overall RMS value.

How to choose

  • To find resonances or characterize the product: sinusoidal, with a low-level sweep.
  • To simulate the transport or service environment: random.
  • For known periodic sources: sinusoidal or a combination with peaks over a random background.
  • To study a specific mode: sinusoidal dwell.

Differences in control

Sinusoidal control adjusts the amplitude at each frequency with a feedback loop. Random control calculates the spectrum of the measured signal and modifies the drive signal to match the target spectrum in real time, with a number of degrees of freedom that determines the statistical confidence of the estimate.

What the engineer sees

A product can pass a sinusoidal test and fail a random one because several modes are excited at once, or vice versa if the resonance coincides with the dwell frequency. That is why many qualification programs combine a resonance sweep, before and after, with the main random test; if the resonant frequency changes, something has loosened or been damaged.