What is evaluated
The test confirms that the product works during and after exposure to low temperature. It differs from cold storage, in which the equipment stays off and is evaluated after returning to ambient temperature. In the operation test the equipment is energized or running, so problems with starting, power consumption and low-temperature behavior are detected.
What changes in the cold
- Electrolytic capacitors lose capacitance and their internal resistance increases.
- Oscillators and clocks change frequency.
- Lubricants thicken and motors need more torque to start.
- Plastics and elastomers harden and can crack or lose their seal.
- Liquid crystal displays respond more slowly.
- Batteries deliver less available energy.
How it is carried out
- The temperature, rate of change and dwell time are defined according to the product requirement.
- The sample is stabilized at temperature, so that the interior reaches equilibrium and not just the surface.
- It is energized or operated while functions, currents and error messages are monitored.
- Functions are verified during exposure and upon return to ambient temperature.
What the engineer sees
Equipment may start without problems while the interior is still warm and fail later, once the cold penetrates. That is why the dwell time and the start after stabilization are the critical moments. Condensation on returning to ambient temperature also needs care, since it can leave moisture on the boards and produce false failures.
How to interpret the result
A failure during the cold that disappears on warming points to a temperature-dependent component. A failure that persists after the return suggests physical damage, such as cracks in solder joints or deformed parts. Temperature and duration values depend on the product specification and the applicable standard, so they must be taken from those documents.