The central idea
Waiting for a product to fail in normal use can take years. An accelerated life test applies more severe stresses, such as temperature, humidity, voltage, vibration or thermal cycling, so that the same degradation mechanisms advance more quickly. The observed times to failure and an acceleration model are then used to extrapolate to use conditions.
What makes it valid
The premise is that the failure mechanism under elevated stress is the same as in service. If the stress is so high that a new mechanism appears, for example melting of a plastic that never softens in use, the test does not represent real life. For this reason the expected mechanism is identified beforehand, and stresses are chosen that accelerate it without changing it.
Components of the method
- Accelerating stress: the variable that is increased, related to the failure mechanism.
- Acceleration model: a mathematical relationship between stress and life, such as the Arrhenius model for thermal processes or power laws for electrical or mechanical stresses.
- Sample and failure criterion: a sufficient number of units and a clear definition of what counts as failure.
- Statistical analysis: life distributions, such as Weibull, and estimation with confidence intervals.
What the engineer sees
The results are presented as times to failure by stress level, an acceleration factor and a life estimate with uncertainty. Data with few failures or with censoring (units that did not fail) have wide intervals, and that width is useful information, not a defect in the report.
Limitations
- It cannot predict failures from random defects of use or installation.
- Several mechanisms can coexist with different accelerations.
- Extrapolating far from the data widens the uncertainty.
When it is worthwhile
When the aim is to compare designs, materials or suppliers, or to demonstrate a target life based on a known mechanism. It does not replace field monitoring or environmental qualification testing.