Technical guides

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • What causes cavitation vibration in pumps?

    Cavitation in a pump produces vibration because the liquid vaporizes in low-pressure zones and the bubbles collapse violently on reaching higher-pressure zones, generating impacts that excite the pump with broadband noise.

  • What Causes Co-Channel Interference?

    Co-channel interference occurs when two or more transmitters use the same channel at the same time within range of each other, so that each receiver also receives the signal that was not meant for it.

  • What causes crosstalk between traces on a board?

    Crosstalk arises from coupling between nearby traces: a mutual capacitance (electric coupling) and a mutual inductance (magnetic coupling) transfer part of the signal from the aggressor trace to the victim. It grows with edge speed and with parallel length.

  • What Causes Discharges in Insulation Cavities?

    Discharges in insulation cavities occur because the gas inside the void has lower permittivity and lower dielectric strength than the surrounding solid, so the field in the cavity is higher and the gas ionizes.

  • What causes interference between a variable-frequency drive and communications equipment?

    The drive switches its output with very fast edges; these abrupt voltage changes generate common-mode currents that flow through the motor cable, through ground and through the power wiring. They couple to the communications equipment by conduction, through the field or through a shared ground.

  • What Causes Intermodulation at a Site with Several Transmitters?

    Intermodulation at a site with several transmitters appears when signals of different frequencies mix in a nonlinear element and generate new products that can fall in a receive channel.

  • What causes localized heating in the core?

    Localized heating in the core is usually due to abnormal eddy currents: a short circuit between laminations, a double core ground or stray flux in structural parts, and it is detected through thermal gases in the oil.

  • What Causes Precision Connector Wear?

    Wear comes from connection cycles, dirt acting as an abrasive, excessive or misaligned tightening, and mating with damaged connectors or connectors of different tolerances. It changes critical dimensions and degrades repeatability.

  • What Causes Saturation of an Analyzer’s Receiver?

    It is caused by an input signal too strong for the first mixer or the analog-to-digital converter, which leaves its linear region and generates harmonics and intermodulation products that do not exist in the real signal.

  • What Causes the Multipath Effect?

    Multipath occurs when the signal reaches the receiver by several paths (direct, and reflected or diffracted by buildings, the ground or objects), and the copies, with different delays and phases, add or subtract, producing fading and intersymbol interference.

  • What causes unstable readings when measuring ground resistance?

    It is almost always one of three things: extraneous currents flowing in the soil, poor contact of the instrument's auxiliary stakes, or stakes placed within the electrode's zone of influence.

  • What causes vibration in electric motors from broken rotor bars?

    Broken bars in the rotor of an induction motor distort the magnetic field and the current, which produces sidebands around the line frequency in the current and variations in the vibration, with modulation at the pole pass frequency.

  • What common errors occur when interpreting a calibration certificate?

    The most frequent errors are reading “calibrated” as “within tolerance”, ignoring the uncertainty, applying corrections with the wrong sign and using the instrument outside the points or conditions the certificate actually covers.

  • What common mistakes occur when verifying zero voltage?

    The main mistakes when verifying zero voltage are trusting an unchecked instrument, measuring only one combination of conductors, using a non-contact detector as definitive proof, and confusing an induced voltage with a true absence of voltage or the other way around.

  • What complements NOM-009-STPS for work at height?

    NOM-009-STPS sets the safety conditions for work at height in Mexico; it is complemented by requirements for personal protective equipment, the selection of fall arrest systems, and rescue and supervision procedures.

  • What condensation is and why it damages equipment

    Condensation occurs when a surface falls below the dew point of the surrounding air and the vapor turns into liquid water on it. That water causes corrosion, leakage and short circuits.

  • What do half digits mean on a multimeter?

    A rating in digits and a half indicates display resolution: full digits can show zero to nine, and the half digit takes only limited values, normally zero or one. It does not indicate the instrument's accuracy.

  • What Do the ITU Radio Regulations Govern?

    They are the international treaty that divides the radio spectrum among radiocommunication services and sets rules for using frequencies and orbits without causing harmful interference between countries.

  • What Does “Anisotropy” Mean in a Material?

    A material is anisotropic when its properties depend on the direction in which they are measured; in an insulator this affects dielectric strength, permittivity, thermal conductivity and expansion.

  • What Does “Dimensional Stability” of an Insulator Mean?

    The dimensional stability of an insulator is its ability to keep its shape and dimensions under temperature, moisture, mechanical stress and the passage of time; if it fails, clearances, fits and insulation distances are altered.

  • What does “electromagnetic disturbance” mean?

    An electromagnetic disturbance is any electromagnetic phenomenon that can degrade the operation of a device, a system or a living being; it is distinct from interference, which is the effect that disturbance produces.

  • What does “leakage current” mean?

    Leakage current is the small current that flows through or across insulation, or along an unintended path to ground, when voltage is applied.

  • What Does “Ampacity” Mean?

    Ampacity is the maximum current a conductor can carry continuously, under the given installation conditions, without its insulation exceeding its permitted temperature.

  • What does “aniline point” mean?

    The aniline point is the minimum temperature at which equal volumes of aniline and oil mix completely; it indicates the aromatic content and, with it, the solvent power of the oil.

  • What does “bias” mean in metrology?

    Bias in metrology is the difference between the average of many repeated indications and the reference value; it is the systematic part of the error, which is not reduced by averaging more readings.

  • What does “billing demand” mean?

    Billing demand is the amount of power, calculated according to the rules of the applicable rate, on which the demand charge is levied, and it does not always match the maximum measured demand.

  • What does “co-channel” mean?

    Co-channel describes two or more transmitters operating on the same frequency channel; the term is almost always used to refer to the interference they cause each other.

  • What does “energized” versus “de-energized” mean?

    Equipment is energized when it is connected to a voltage source or could be, even if it is switched off; it is de-energized only when it has been isolated from all sources, locked out, verified free of voltage and its stored energy discharged.

  • What does “EVSE” mean?

    EVSE stands for Electric Vehicle Supply Equipment: the supply equipment that connects the electric vehicle to the grid and safely controls when and how much energy it receives.

  • What does “functional failure” mean?

    A functional failure is the loss of an item's ability to perform a function at the level of performance expected of it, even though it remains physically intact. It is defined by what the equipment can no longer do, not by which component broke.