Technical guides

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • Differential probe or two channels with math subtraction?

    A differential probe rejects common mode with electronics designed for that purpose, whereas two channels with math subtraction depend on both channels and probes being perfectly matched; they are only justified for low-frequency signals with little common mode.

  • Digital or analog oscilloscope?

    Today a digital oscilloscope is the usual choice because it stores, shows what precedes the trigger and measures; an analog one shows the signal in real time without digitizing it, and it remains useful when intensity variation or immediate response matters.

  • Dipole or Monopole Antenna?

    A dipole is a two-arm antenna that needs no ground plane; a monopole is a single arm over a conductive plane that, by the image principle, behaves like half a dipole, with half the theoretical impedance.

  • Direct measurement or instrument transformers in power quality

    Direct measurement is limited to voltages and currents within the analyzer's range and measurement category; at higher levels, potential and current transformers are used, which reduce the signals but add ratio error, phase error and frequency response limits.

  • Direct-On-Line, Wye-Delta or Soft Starter?

    The choice between direct-on-line, wye-delta and soft starter depends on how much starting current and torque the supply and the load can tolerate: direct-on-line is simple but abrupt, wye-delta reduces the current with a torque jump, and the soft starter controls it gradually.

  • Distribution or power transformer: how do they differ?

    There is no single dividing line: a distribution transformer feeds loads close to the user at lower voltages and with variable operation, while a power transformer interconnects grid voltage levels with greater capacity and more control and protection accessories.

  • Do thermoelectric voltages cause errors in low-level measurements?

    Yes. Wherever dissimilar metals join and there is a temperature difference, a small voltage appears through the Seebeck effect and adds to the signal, and in low-level measurements it can be comparable to or larger than what you want to measure.

  • Dry-type or oil-immersed transformer?

    An oil-immersed transformer cools better and handles more power and voltage, while a dry-type unit avoids oil and reduces fire risk, but has limits on size and environment.

  • Electronic regulator or constant-voltage transformer?

    An electronic regulator corrects slow voltage variations using switched taps or a servo element, with an output that keeps the input waveform; a constant-voltage (ferroresonant) transformer regulates through core saturation, isolates and tolerates brief sags, but delivers a more distorted waveform and depends on the load.

  • EMC requirements set by IEC 61326-1 for laboratory equipment

    IEC 61326-1 sets electromagnetic compatibility requirements for electrical equipment for measurement, control and laboratory use: it limits the emissions the equipment produces and requires a certain immunity to external disturbances.

  • Epoxy or polyester resin as an insulator?

    Epoxy resin usually outperforms polyester in adhesion, dimensional stability, chemical resistance and electrical properties under humidity, while polyester is less expensive, cures quickly and serves in less demanding applications.

  • Ferrite on the cable or filter at the input?

    A ferrite is a quick, inexpensive fix, useful for common mode on a specific cable; an input filter is an engineered solution that acts on both common mode and differential mode and protects the entire input. If a cable already has a problem, a ferrite lets you test; if you are designing, a filter is the right choice.

  • Fixed or automatic power factor correction?

    Fixed correction always delivers the same kvar and works when reactive demand is stable; automatic correction switches steps in and out under a controller and works when reactive demand varies during the day.

  • Fixed or Variable Attenuator in a Measurement Chain?

    Use a fixed attenuator when you need a stable level and good matching; use a variable one when the level must be adjusted during the measurement. The fixed type is more repeatable; the variable type is more flexible and less accurate.

  • Flat or spherical electrodes in the oil dielectric strength test

    The difference between flat and spherical electrodes lies in the shape of the electric field: flat electrodes produce a more uniform field and a test less sensitive to contaminants, while spherical or rounded-profile electrodes produce a more divergent field and detect water and particles better.

  • Forced or natural ventilation in a confined space?

    Natural ventilation depends on wind and temperature differences, which cannot be controlled or guaranteed; forced ventilation uses fans and does allow the flow to be directed and assured, which makes it the reliable option when people or contaminants are inside.

  • Free space or transmission line for measuring materials?

    Free space suits high frequencies, large flat parts and tests without contact or machining; a transmission line offers greater accuracy and broad bandwidth at lower frequencies, but requires a machined sample that fits the section well.

  • Function generator or arbitrary waveform generator

    A function generator is enough if the test uses standard waveforms such as sine, square or triangle; an arbitrary generator is needed when you must reproduce a captured signal, a special pulse or a specific sequence.

  • Fuse or Circuit Breaker to Protect a Circuit?

    A fuse protects by melting an element that is destroyed when it operates, with a great ability to limit fault current, while a circuit breaker opens a mechanism that can be reset and offers settings and additional functions.

  • Gauge or absolute pressure for an application?

    Gauge pressure is chosen when the difference from the surroundings matters, and absolute pressure when the value relative to vacuum matters; the key is whether variation in atmospheric pressure affects what you want to know.

  • Grid or perimeter ring?

    A grid controls voltages across its whole area thanks to its internal conductors; a perimeter ring surrounds the installation but leaves the interior without conductors of its own, so it is used in small areas or where the contact risk is low.

  • Grid-tied or off-grid system with batteries?

    A grid-tied system delivers energy to and receives energy from the grid and needs no batteries; an off-grid system must supply the load on its own and requires storage. The decision depends on whether a reliable grid is available at the site.

  • Ground testing with stakes or a clamp: when is each one the better choice?

    Measuring with stakes (fall of potential) is the better choice when the absolute value of an electrode or a grid is needed; the clamp suits quick checks on systems with several interconnected electrodes and no room to lay out probes.

  • Half-cell or full-cell module?

    A half-cell module uses cells cut in half, so that each one carries half the current. This reduces resistive losses and improves behavior under partial shading compared with a full-cell module.

  • Handheld or benchtop multimeter: which to choose

    A handheld multimeter suits field diagnostics, mobility and safety in electrical installations; a benchtop unit suits laboratory measurements where resolution, stability and repeatability matter.

  • Handheld vibration meter or full analyzer?

    A handheld vibration meter gives an overall vibration level to detect whether a machine is within normal limits, while a full analyzer shows the spectrum and waveform to reveal why it vibrates; the choice depends on whether you need to monitor or to diagnose.

  • How a compressed air line is checked for leaks

    Leaks are located with ultrasonic detection or soap solution, and their size is quantified by measuring consumption with the process stopped or the pressure drop in a known volume.

  • How a dry heat test is performed

    The sample is brought to a high temperature in a chamber with low-humidity air, held until its interior stabilizes, and checked for condition and operation, either during exposure or afterward.

  • How a dust exposure test is performed

    The enclosure is exposed to standardized dust in a chamber that keeps it in suspension or blows it onto the sample, with or without an internal pressure difference, and it is then checked for dust ingress and for correct operation of the equipment.

  • How a mechanical shock test is performed

    The sample is subjected to a brief acceleration impulse with a defined pulse shape, amplitude and duration, applied in specified directions, and is then checked, or monitored during the event, for damage or loss of function.