First locate, then quantify
A compressed air leak is a problem not only because of the air that is lost: it forces the compressor to work harder to maintain pressure, and that means energy. Checking the line involves two distinct tasks: finding where it leaks and estimating how much is lost.
How leaks are located
- Ultrasonic detector: a pressurized gas leak produces a high-frequency turbulent sound that the instrument converts into an audible tone, and it works even in noisy environments.
- Soap solution: applied to joints and fittings, it forms bubbles wherever there is a leak. It is simple and well suited to accessible points.
- Visual and audible inspection during quiet hours, although this misses small leaks.
The most frequent points are threaded connections, quick couplers, worn hoses, valves, filters, regulators and automatic drains.
How leaks are quantified
With production stopped and the line pressurized, the compressor keeps loading to replace the loss; the percentage of time it runs loaded, or the flow measured at the supply, indicates the size of the leaks. Another option is to isolate a section of known volume and measure the pressure drop over a defined time, from which the leak flow rate is estimated using the relationship between volume and pressure change.
What the engineer sees
A system with leaks shows a compressor that loads and unloads very often with no demand, line pressure that falls during breaks, and high electricity consumption for the production achieved. After repairs, the load cycle is seen to lengthen.
How to close the loop
Each leak found should be logged with its location, repaired and measured again, and the inspection repeated periodically. Before working on pressurized lines, the system must be depressurized and secured; interventions are a job for trained personnel.