Two tests, two mechanisms
In the constant humidity test, temperature and relative humidity are held fixed for a long period. Water absorption by the materials and the formation of thin surface films predominate. In the cyclic test, the temperature rises and falls while the humidity stays high, so that the surface cools below the dew point and liquid water can condense.
Why condensation matters
Liquid water carries contaminants, forms conductive bridges between traces and accelerates corrosion. In addition, when the air inside an enclosure heats and cools, it expands and contracts, and “breathes” through gaskets and openings. Each cycle can bring in moist air that condenses inside. Constant humidity does not reproduce that pumping.
What fails in each test
- Constant: reduced insulation resistance, absorption in laminates and encapsulants, slow electrochemical migration, contact corrosion.
- Cyclic: condensation on circuit boards, intermittent leakage, delamination from cycling stresses, localized corrosion, seal failure.
When to use each one
Constant humidity is suitable for verifying behavior in stable tropical environments or for insulation degradation tests with voltage applied. Cyclic humidity is chosen when the product lives outdoors or in environments with daily temperature changes, and when the protection provided by the enclosure and conformal coatings is to be evaluated.
What to watch
Make sure there is no dripping from the chamber ceiling onto the samples, because falling water does not represent condensation on the part. It must also be decided whether the product is operating or switched off: energized equipment heats up and avoids part of the condensation, while equipment that is off suffers more. Both conditions may be relevant.
How to interpret the result
Function and insulation are compared before and after, and corrosion and residues are inspected. If the product withstands the cyclic test, it normally withstands the constant test as far as condensation is concerned, although not necessarily with regard to prolonged absorption. The choice should therefore respond to the failure mechanism of concern.