Anechoic Chamber or Open-Area Test Site?

An anechoic chamber offers a controlled environment protected from external noise and weather, while an open-area site allows large equipment to be measured with a known ground reflection but exposes the measurement to ambient noise.

Two ways to control the environment

Every antenna and radiated emissions measurement needs an environment whose effect is known. An anechoic chamber achieves this by eliminating reflections with absorber and shielding the enclosure. An open-area site achieves it with clear terrain and a metal ground plane, so that the only significant reflection is from the ground, and its contribution can be predicted.

Comparison

Aspect Anechoic chamber Open-area site
External noise Isolated by the shielding Present: radio, television and other sources
Weather Independent Can interrupt the measurement
Object size Limited by the enclosure Large objects can be measured
Reflections Reduced by absorber Ground reflection, known and intended
Repeatability High More dependent on conditions

When each one is preferred

  • Anechoic chamber: radiation patterns, gain and sensitive measurements that external signals would affect, or when repeatability and continuous work are required.
  • Open-area site: very large or heavy equipment, and emissions measurements that were historically defined for that environment.

What the engineer sees in the data

On an open-area site, the received level varies with antenna height, because the direct signal and the signal reflected from the ground add or subtract. That is why a height scan is performed to find the maximum. In an anechoic chamber that variation does not exist, but ripple can appear from residual reflections off the absorber.

When neither is enough

Some emissions chambers are not fully anechoic but have a reflective floor to emulate an open-area site, and they are called semi-anechoic. For low frequencies, where absorber is not very effective, an open-area site or an equivalent site may remain the reference.