What is measured
A regulated supply tries to keep its output voltage constant. Regulation expresses how well it manages this in the face of two disturbances: a change in load current and a change in input voltage. The first is load regulation and the second is line regulation. They are expressed as the voltage variation, absolute or percentage, over the range of variation of the disturbance.
Load regulation
- Connect a load that allows the current to be varied in a controlled way. A programmable electronic load is the most convenient.
- Measure the voltage at the output terminals with a voltmeter of sufficient resolution, using dedicated sense leads. If the supply has remote sensing, connect it at the point where regulation is wanted and measure at that same point.
- Record the voltage with a light load, then record it again with the maximum specified load. Allow time for the supply and the voltmeter to stabilize.
- The difference between the two values is the change due to load.
Line regulation
The load is held constant and the input voltage is varied over the specified range, using a variable autotransformer or a controlled AC source. The change in output voltage is recorded. This test works with line voltage, and it must be carried out by qualified personnel in accordance with electrical safety regulations.
Precautions
- Measure at the terminals and not at the end of long cables, which add a current-dependent voltage drop.
- If the voltmeter and the load share the same leads, the drop in them is added to the result; use separate leads for sensing.
- Watch for heating: the output voltage may drift while the supply warms up at high load.
- Distinguish static regulation from transient response, which is studied with a load step and an oscilloscope.
How to interpret the result
Good regulation means little variation. If the measurement turns out worse than the specification, first check the connections and measurement points. Output ripple and noise are a separate measurement, distinct from regulation, and are measured with a bandwidth-limited oscilloscope and AC coupling.