What is the lower explosive limit?

The lower explosive limit (LEL, or LIE in Spanish) is the minimum concentration of a flammable gas or vapor in air at which the mixture can ignite; below it, the mixture is too lean to burn.

Definition

For a gas or vapor to burn, three things are needed: fuel, oxygen and an ignition source. But the proportion of fuel in the air matters. If there is too little, the flame does not propagate. The lower explosive limit is the minimum concentration at which the mixture can ignite. Above it, and up to another value called the upper explosive limit (UEL, or LSE in Spanish), the mixture is flammable. Above the upper limit, the mixture is too rich in fuel and does not burn, although it can become flammable when diluted with air.

Each substance has its own

The LEL is a property of each gas or vapor and depends on conditions such as temperature and pressure. Some gases have a narrow flammable range and others a very wide one. That is why a detector calibrated with one gas does not measure a different gas with the same accuracy unless a correction factor is applied.

How a detector reports it

Portable instruments usually display the result as a percentage of the LEL, not as a percentage of gas in air. A reading of zero percent means no detectable flammable gas; a reading of one hundred percent means the mixture has reached the lower limit, that is, it is already capable of burning. Alarms are set at a small fraction of the LEL, to give room to act long before reaching it.

What the engineer learns from this scale

  • A low %LEL reading is not “low risk” in itself: it is a warning that a gas source is present.
  • The reading can rise quickly over time, so its trend is watched and not just its value.
  • A reading that rises and then falls to zero may indicate that the mixture has become too rich, not that the gas has gone, especially with catalytic sensors. That is why it is interpreted together with the oxygen measurement.

Relationship to the confined space

In an enclosed space, vapors from solvents, fuels or process gases can build up until they approach the LEL. The measures are to ventilate, eliminate ignition sources, use equipment suitable for explosive atmospheres and measure continuously.

A sample reading

If a measurement taken from the access point gives a reading below the alarm level, the engineer still asks whether sampling reached every zone, whether the sensor is suitable for that vapor and whether the planned work will generate more of it. Interpretation and entry are the responsibility of trained personnel, in accordance with applicable regulations.

This guide is for information only. Work involving electrical hazards, heights or hazardous atmospheres must be carried out by qualified, authorized personnel in accordance with applicable regulations.