Definition
The entry supervisor is the person answerable for ensuring that entry takes place under acceptable conditions. The supervisor’s signature on the permit means they have confirmed, before authorizing, that the hazards have been identified, the control measures applied and the resources organized. It is a decision-making responsibility, not just paperwork.
What they verify before authorizing
- That the hazards of the space and of the planned work have been identified.
- That atmospheric tests were done with suitable instruments and under acceptable conditions.
- That the space is isolated from lines, energy sources and hazardous materials.
- That protective, communication and ventilation equipment is available and working.
- That a rescue service is available and can respond in time.
- That the designated people know their roles.
What they do during entry
They retain responsibility for as long as the permit is in force. They verify that the conditions continue to be met, address changes in the work, control who enters and, when appropriate, end the entry and cancel the permit. They can also transfer the role to another supervisor at a shift change, with an explicit handover. The role may coincide with that of other people, provided the requirements of each role are met and the regulations do not prohibit it.
When they cancel the entry
On an atmosphere alarm, a change in the work that introduces new hazards, a condition not foreseen in the permit or any sign that the barriers are not working. During a rescue, they do not personally enter unless trained and equipped to do so.
What an engineer sees in practice
A permit with date, time, readings, signature and test records, an identifiable person walking the area and verifying, and a clear procedure for stopping the work. When everyone assumes that “someone else” checked, the supervisor is the person who cannot delegate that question.
How to interpret the role
Its value lies in the informed decision to enter or not to enter. It requires training and must be designated in accordance with the applicable safety regulations; this role belongs to qualified personnel.