Definition
Every device adds some noise of its own, generated mainly by thermal agitation in resistances and by processes in semiconductors. As a result, the signal-to-noise ratio at the output is worse than at the input. The noise factor is the ratio of the input signal-to-noise ratio to the output signal-to-noise ratio; the noise figure is that factor expressed in decibels. An ideal device with no noise of its own would have a factor equal to one, that is, zero decibels. The standard definition assumes that the input noise is that of a matched source at a conventional reference temperature close to room temperature.
Relationship with noise temperature
A device’s own noise can also be described as an equivalent noise temperature: the temperature at which a resistance at the input would have to be to produce that additional noise. Factor and temperature are converted into each other using the reference temperature. Equivalent temperature is more convenient in very sensitive systems, such as satellite receiving systems.
Cascaded stages
In a receiver with several stages, the total factor depends on the factor of each stage and on the gain of the preceding ones. The Friis formula states that the total factor is that of the first stage, plus the excess noise of the second divided by the gain of the first, and so on. The practical consequence is that the first stage dominates: if it has good gain and low noise, the noise of the following stages is attenuated in proportion. This is why a low-noise amplifier is placed as close as possible to the antenna.
Passive losses
A lossy passive element, such as a cable or filter, at room temperature has a noise figure equal to its loss, measured in decibels. A lossy cable ahead of the amplifier adds directly to the system figure, which explains why the cables between the antenna and the first amplifier must be as short as possible.
What an engineer sees in practice
- A lower noise figure makes it possible to detect weaker signals or achieve the same quality with less power.
- The figure depends on frequency, bias and source impedance; it is not a single number.
- A device with high gain but a poor input match can have more noise than expected.
An example
If a receiver has an initial amplifier with a low figure and good gain, followed by a noisy mixer, the total figure is almost that of the amplifier. If the order is reversed, the mixer dominates and the total figure becomes markedly worse.