What is the International Vocabulary of Metrology?

The International Vocabulary of Metrology, known as the VIM, is the document that defines the fundamental terms of metrology, such as quantity, calibration, traceability and uncertainty, so that they are used with the same meaning everywhere.

The VIM is the common reference for metrological language. It brings together precise definitions of concepts that are confused in everyday speech, such as accuracy, precision, error, uncertainty and calibration. Its practical value is to avoid misunderstandings among laboratories, customers, manufacturers and regulators. Consult the current edition, since the definitions have been revised over time.

How it is organized

It groups terms by topic, from the general to the specific:

  • Quantities and units.
  • Measurement: principle, method, procedure, result.
  • Measuring devices: instrument, measuring system, sensor, transducer.
  • Properties of devices: sensitivity, resolution, stability, drift.
  • Standards: primary standard, secondary standard, working standard, reference material.
  • Results and their properties: accuracy, trueness, precision, repeatability, reproducibility, uncertainty, traceability.

Some definitions that change how people talk

  • Calibration: an operation that establishes a relation between the values with uncertainties provided by standards and the corresponding indications, and then uses this information to obtain a result from an indication. It does not include adjustment.
  • Measurement accuracy: closeness between a measured value and a true value of the measurand. It is a qualitative concept and is not expressed as a number.
  • Metrological traceability: a property of a result whereby it can be related to a reference through an unbroken chain of calibrations.

What the engineer sees in practice

Laboratory standards and the uncertainty guide use their terms with the VIM meaning. If a procedure says “adjustment” or “verification”, bear in mind that the VIM distinguishes them from calibration. Going to the vocabulary avoids arguments in which two people use the same word for different things.

When to consult it

When drafting procedures, certificates, specifications or contracts, to choose the correct term, and whenever there is doubt about how to interpret a technical standard.