24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

What Is the Loss Factor of a Dielectric?

The loss factor, also called tan δ or dissipation factor, is the ratio between the resistive current (which turns into heat) and the capacitive current flowing through a dielectric under alternating voltage.

What exactly it measures

A real insulator is not a perfect capacitor. When alternating voltage is applied, an almost purely capacitive current flows, leading the voltage by 90 degrees, plus a small component in phase with the voltage that represents the losses. The loss factor is the tangent of the angle δ, the amount missing to complete those 90 degrees; it equals the ratio of the resistive component to the capacitive component. It is a dimensionless quantity and does not depend on the dimensions of the sample, which makes it possible to compare different pieces of the same material.

Where the losses come from

  • Conduction: ions or impurities that move under the field, dominant at low frequency and high temperature.
  • Dipolar polarization: polar molecules reorient with the field and dissipate energy through internal friction.
  • Partial discharges or surface leakage that add to the measurement.

What an engineer sees in practice

The value changes with frequency, temperature and applied field, so an isolated number says little. An increase with temperature usually indicates ionic contamination or moisture; an increase as the voltage rises suggests ionization in internal voids. In equipment insulation, the trend between measurements made under comparable conditions is more informative than a single value.

Why it matters

The power dissipated in the dielectric is proportional to the frequency, the capacitance, the square of the voltage and tan δ. If the material heats up, its losses usually grow, which can lead to a vicious circle of heating that ends in thermal failure. That is why it is a selection parameter for materials for capacitors, cables and high-frequency applications.

How it is measured

Capacitance and loss measurement bridges or impedance instruments are used, with electrodes of defined geometry, at a stated frequency and temperature. Sample preparation, humidity conditioning and the guard electrode directly influence the result.

How to interpret the result

Always compare against the same material under equivalent conditions, or against the criterion of the manufacturer or the applicable standard. Measurements on energized or high-voltage equipment must be performed by qualified personnel, following current safety regulations.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer