Definition
In reliability, the term common cause failure applies when several failures occur from the same origin and not independently. The naive redundancy calculation assumes that each channel fails separately, so that the probability of two failing at once is the product of the individual probabilities. A common cause breaks that assumption: the channels go down together and redundancy contributes less than expected.
Where they come from
- Identical design: two channels with the same component, the same firmware or the same design defect share the same latent error.
- Shared environment: high temperature, humidity, vibration, dust, flooding or a fire that affect both channels because they are in the same enclosure or the same room.
- Common power or utilities: the same power supply, the same panel, shared compressed air or cooling.
- Maintenance and operation: an incorrect calibration applied to all instruments, or the same faulty procedure carried out by the same person on both channels.
- Manufacturing lot: components from the same lot with a defect or with similar aging.
- External disturbances: overvoltages, electromagnetic interference or a lightning strike that reach all connected equipment.
Why it is hard to see
Each channel appears healthy when tested separately. The common cause usually remains latent until an event activates it for all of them at the same time. In addition, the failure rate data for each component do not reflect it, because it arises from the relationship between the channels and not from any one of them.
How it is reduced
- Physical and electrical separation: independent routes, enclosures and power supplies.
- Diversity: use different technologies, manufacturers or measurement principles for the same purpose, so that they do not share the same defect.
- Staggered maintenance: do not calibrate or work on all channels at the same moment or with the same person without cross-checking.
- Comparison tests: check redundant channels against each other to detect deviations.
- Explicit analysis: include common cause in the reliability analysis, often with a factor that takes a fraction of the total failure rate.
An example
Two backup pumps fed from the same panel appear redundant. If the panel loses voltage, both stop. The redundancy protected against the failure of one pump, but not against the failure of the service both share.