Definition
In most dielectrics, polarization exists only while a field is present. In a ferroelectric, certain phases of the crystal structure lack central symmetry, and the material has a permanent polarization within each cell. What is characteristic is that the direction of this polarization can be reversed by applying a sufficient field.
Domains and hysteresis
The material is organized into domains, regions with the polarization oriented in the same direction. An applied field makes the domains aligned with it grow. Plotting polarization against field gives a hysteresis loop, similar to that of ferromagnetic materials, with a remanent polarization when the field returns to zero and a coercive field to reverse it. The area of the loop represents the energy dissipated.
Transition temperature
Above a critical temperature, called the Curie temperature, the material changes to a phase without spontaneous polarization and behaves like an ordinary dielectric. Near that temperature the permittivity reaches very high values, and this is exploited in ceramic capacitors with high capacitance per volume. Well-known examples are barium titanate and lead zirconate titanate ceramics.
Associated properties
Many ferroelectrics are also piezoelectric, since a mechanical stress produces polarization and vice versa, and pyroelectric, since a change in temperature generates charge. These properties make possible sensors, actuators and infrared detectors.
What the engineer sees
The permittivity of a ferroelectric is not constant: it depends on temperature, the applied field and prior history. Capacitors of this type lose capacitance with applied DC voltage and with time, an aging phenomenon linked to the domains. They also exhibit nonlinearity and higher losses than other dielectrics.
Applications
Ceramic capacitors, ultrasonic transducers, piezoelectric actuators, sensors and non-volatile memories based on polarization reversal.
How it is characterized
The hysteresis loop is measured with a suitable circuit, along with permittivity against temperature and frequency. The measurement requires high voltages and must be carried out by qualified personnel following the applicable safety regulations.